4.7.11

SWEEPING UNIT SUCTION FILTER AND FILTER SHAKING MOTOR REPLACEMENT

Before carrying out these operations remove the key from the dashboard;
open the machine front guard (figure 4.35)
lift the box lid (figure 4.36)
loosen the two hex screws and remove the frame (detail 1 figure 4.37)
remove the filter shaking motor support (detail 2 figure 4.37)
unplug the filter shaking motor connector;
lift and replace the damaged or clogged filter (detail 3 figure 4.37)
now reverse the order of the above operations
FIGURE 4.35
3
Rev. 001
MAINTENANCE
FIGURE 4.37
22/12/2014
I115SS
FIGURE 4.36
2
1
42/58