5.4

HOPPER ASSEMBLY

Place the hopper on its fl ange. Make sure gasket is in its place. Then secure the
bolts using the nuts. Adjust the foot on the adjustable leg so that the auger assem-
bly is supported.
5.5
CONNECTING HOPPER TO MAIN UNIT
First, screw "stud bolts" into the welded nuts on the side wall of main
unit. Put the hopper on its bottom fl ange. Then, align the holes on
the side of hopper with threaded stand offs. Take 2 bolts & pass
them through the holes and screw them with "threaded stand offs".
Squareness of hopper to furnace can be adjusted while tightening
stud bolts.
5.6
FUEL WARNING SWITCH ASSEMBLY
Fuel warning switch is as seen in picture-1. Install it through the hole available at the bottom of hopper. Re-
move one ring fi rst, pass the switch through the hole, then screw the ring from inside. Secure it with the ring
outside the hopper. Switch should be in about 1". Please see picture-2. Gearbox cable has a special plug for
the "fuel switch connection". Please connect "fuel switch cable plug" here, picture-1 & 3.