7-3. Welding Power Source And Remote Diagnostics Help Codes

Display Code
H01
H02
H03
Secondary Circuit Over Temperature
H04
Primary Temperature Sensor Malfunction
H05
H06
H08
H12
H13
H16
PC2 Temperature Sensor Malfunction
H17
H18
PC3 Temperature Sensor Malfunction
H19
H20
H21
Primary Input Line Voltage Malfunction
H22
H26
H27
H30
H32
Accessory Temperature Sensor Malfunction
H33
H96
H97
H98
H99
H
Display Example
Fault
Primary Transformer Over Current
Secondary Thermistor Malfunction
Primary Circuit Over Temperature
Current Foldback
Output Over Voltage Malfunction
Precharge Incomplete
Internal Voltage Malfunction
PC2 Over Temperature
PC3 Over Temperature
PC2 Power Supply Low
Boost Fault
Button Stuck On Power Source
Polarity Switch Fault
Stuck Contactor TIG/Stick
Accessory Over Temperature
PC7 Communication Malfunction
PC1 Communication Malfunction
Serial Communication Loss
Serial Communication Malfunction
0
1
Indicates a malfunction in the primary power circuit.
Indicates the left side thermal protection circuitry is
malfunctioning.
Indicates left side of unit has overheated. Unit has shutdown to
allow fans to lower left side temperature. Operation will continue
after unit is within normal temperature range.
Indicates the right side thermal protection circuitry is
malfunctioning.
Indicates right side of unit has overheated. Unit has shutdown
to allow fans to lower right side temperature. Operation will
continue after unit is within normal temperature range.
Indicates operation at maximum input current.
Output voltage exceeded 100 VDC for more than 1/2 second.
Precharge did not complete in allotted time.
System cannot measure output voltage.
Indicates thermal protection circuitry on the Process Control
board is malfunctioning.
Indicates PC2 has overheated. Unit has shutdown to allow fans
to lower temperature.
Indicates thermal protection circuitry on the System Power
board is malfunctioning.
Indicates PC3 has overheated. Unit has shutdown to allow fans
to lower temperature.
Indicates the control supply on PC2 is malfunctioning.
Indicates input primary line voltage is too low.
Primary line voltage must be at least 90% of specified nominal
voltage.
Indicates the boost circuitry on the right side of unit is
malfunctioning.
Indicates button is stuck on the power source upon start up.
Fault will clear when button is released.
Indicates the relay circuitry (W1, W2) is malfunctioning.
Indicates a stuck remote contactor in either Stick or TIG pro-
cess.
Indicates the thermistor in the attached FieldPro accessory is
malfunctioning.
Indicates the attached FieldPro accessory has overheated.
Indicates internal communication malfunction to PC7.
Indicates internal communication from primary power circuitry
to secondary power circuitry on PC1.
Indicates serial communication was initially made and is now
malfunctioning. May appear normally during firmware updates.
Communication between PC1 and PC5 malfunction.
Indicates serial communication is malfunctioning. May appear
normally during firmware updates. Communication between
PC1 and PC5 malfunction.
Description
OM252932 Page 35