Safety Instructions - Bauer MSXH Operating Manual

Submersible motor mixer
Table of Contents

Advertisement

The red light for probe 1 or 2 is on:
(Note: tripping device RDA 02 has turned the motor off)
Turn the switch for mode of operation to 0
Press reset key for about 3 seconds
Red light goes out – put turn switch to the required position after 15 seconds
The motor is starting up again.
The red light „continues lightening":
Check if
probes are really submerged
the mixer is not enough submerged
there is a loss of fluid inside the tank
Remedy the cause of the malfunction
Lower the mixer until the probes are below medium surface.
Add medium.
Tune the operating threshold of the potentiometer with the medium
Repeat start-up operation :
The red light of the leak detector lights up:
(Note: tripping device RDA 01 has turned the motor off)
Turn the switch for mode of operation to 0
Put main switch into position „0", wait for 5 seconds, put it back to position „1" (power supply on)
(This operation comes up to a reset function of the tripping device).
If the light continues lightening check the mixer for leaks.
02

6.3.7 Safety instructions

Always shut down the power supply before working on the starter.
Operating Manual for BAUER Submersible Mixer/ Version I-2013
Adjustment of the potentiometer for transmitting the medium not correct
Adjust sensitivity
28