B 17 Operating hour meter
The current operating hours are shown on the display
There is no need to set anything
See operating hours :
Press key ESC
The display is showing the following
>Stop
Set Param
Set
Prg Name
Confirm with key ▼ , choose „Set Param" and confirm with key OK
The display is showing the following
B9
D =MTWTFSS
On = 22:00
Off = 04:00
Confirm 3 times with the key ▼
The display is showing the following
B17
MI =
1h
MN=
1h
OT =
0h
OT displays the consumed operating hours
Do not change parameter MI and MN !!
Press 2 times ESC for returning to the main menu