5 ELECTRICAL CONNECTION

The electrical connection must imperatively be carried through by an approved electrician. The three-
phase motor is protected from phase failure, low voltage and overloading by the thermal coil protection (PTC
thermistors) together with the tripping device. Upon request, Bauer supplies fully wired electrical control units
ready for connection. Weatherproof installation of the electrical control is recommended (inside a building or under
a weather-proof hood at the manure tank).
All mixers are equipped with an 8 m long electric cable (cable Ø 20 mm). The cable connection to the motor must
not be dismounted!
Fix the electric cable to the traction rope by means of a stainless bolt-snap, which enables the cable to follow
automatically lifting and lowering movements of the mixer. Attach the cable to the rope by means of the provided
rope strap about 1 m above the upper edge of the console (see drawing) in order to prevent the cable loops from
getting into the mixing propeller when lifting the mixer. Attach the upper-most bolt-snap to the backing plate.
Check cable length to make sure the cable is not under traction when the mixer is completely lowered! Take care
to place the cable in wide loops in order to prevent it from folding.