Graco 96G017 Instruction Manual page 59

G3 max automatic lubrication pump
Hide thumbs Also See for 96G017:
Table of Contents

Advertisement

Cycle /
Pressure
Fault
HH
MM : SS
Machine
Count Fault
HH
MM : SS
332305B
MM
SS
##
!
ON
OFF
HH : MM
C
1
P
C
C
1 2 3
2
P
C
P
3
P
MM
SS
##
!
ON
OFF
HH : MM
C
1
P
C
C
1 2 3
2
P
C
P
3
P
In pressure mode indi-
cates that unit is over pres-
surized or a lubrication
cycle was not completed in
the user-defined amount of
time.
In cycle mode indicates
that a cycle was not com-
pleted in the user-defined
amount of time.
LED corresponding to the
affected sensor input
blinks.
Could be more than one
sensor alarm at the same
time.
Unit has not received the
correct number of machine
counts in the user defined
Backup Time.
Alarms
Examine system to deter-
mine if you have a
plugged or broken line or
other component failure,
i.e., divider valve, injector.
Press and
hold the
RESET but-
ton to clear
fault.
Examine system to deter-
mine if the machine sen-
sor is operating properly.
Press and
hold the
RESET but-
ton to clear
fault.
59

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G3-g-24mx-2l0l00-10cv00r0G3-g-acmx-2l0l00-1d0v000096g01896g02096g019G3-g-24mx-2lfl00-10cv00r0 ... Show all

Table of Contents