Rheem 97MDV060 Series Installation Instructions Manual page 88

(-)97v series upflow condensing modulating, communicating gas furnaces w/ecm blower (-)97v series
Table of Contents

Advertisement

INTEGRATED FURNACE CONTROL
THERMOSTAT WIRING DIAGRAMS-CONDENSING UNIT (NON-
COMMUNICATING
E. HEAT PUMP SYSTEMS W/LEGACY THERMOSTATS
E1. WIRING OF A SINGLE-STAGE LEGACY
THERMOSTAT WITH AUTOSTAGING SELECTED
(SEE FIGURE 61).
FIGURE 61
ING DIAGRAM FOR A LEGACY SINGLE-STAGE THERMOSTAT WITH AUTOSTAGING.
WIRING DIAGRAM FOR A LEGACY SINGLE-STAGE THERMOSTAT WITH AUTOSTAGING.
SINGLE-STAGE
THERMOSTAT
(NON-COMMUNICATING)
ST-A1194-92-01
A1194-92-01
88
TWO-STAGE / MODULATING
GAS FURNACE CONTROL
1
2
R
C
HUM STAT
W1
W2
G
Y1
Y2
JUMPER
B
NOTE: 1.) FOR TIMED STAGING, THE DIPSWITCHES 10 AND 11 (S2-10 AND S2-11)
MUST NOT BE LEFT IN THE "OFF" POSITION. IF THE SWITCHES ARE
LEFT IN THE "OFF" POSITION WITH THIS CONFIGURATION, THE FURNACE
WILL NEVER GET TO HIGH STAGE HEAT. (SEE DIPSWITCH SECTION
OF THIS BOOK).
2.) FOR SINGLE STAGE COOLING A JUMPER BETWEEN Y1 AND Y2 IS REQUIRED.
E2. WIRING OF A TWO-STAGE LEGACY THERMO-
STAT (SEE FIGURE 62)
OUTDOOR
D
UNIT