Rheem 97MDV060 Series Installation Instructions Manual page 89

(-)97v series upflow condensing modulating, communicating gas furnaces w/ecm blower (-)97v series
Table of Contents

Advertisement

THERMOSTAT WIRING DIAGRAMS-CONDENSING UNIT (NON-
COMMUNICATING
FIGURE 59
WIRING DIAGRAM FOR A LEGACY 2-STAGE THERMOSTAT.
FIGURE 62
WIRING DIAGRAM FOR A LEGACY 2-STAGE THERMOSTAT
ST-A1194-93-01
19. 24VAC AND COMMON CONNECTIONS (E10/E11)
For connection to the low voltage side of the control
transformer. Terminals are ¼" quick-connect style.
INTEGRATED FURNACE CONTROL
TWO-STAGE / MODULATING
GAS FURNACE CONTROL
1
2
R
C
HUM STAT
W1
W2
G
Y1
Y2
B
20. FUSE (P100/P101)
A fuse is provided to protect low-voltage (24VAC)
circuits from shorts between 24VAC and Ground or
Common. A fault code 30 is displayed at the furnace
control when the fuse has been opened.
D
ST-A1194-93-01
89