Edit Date (cont'd)
4
130
S
S
S
S
S
S
S
S
S
The date/time stamp behavior is as follows:
During warm-up:
-
The date/time displayed starts from 1970 and increments from there. If the ED-
DAT command is used to set the time in local mode, the time is changed as
specified in the command.
After warm-up:
-
If the ED-DAT command has not been used to set the local mode time, then
UTC date and time are displayed.
-
If the ED-DAT command has been used to set the local mode time, then it is
changed in the manner described as follows.
-
The date given in the ED-DAT command is retained. The local hours, minutes,
and seconds are set to the nearest 30-minute divisible difference from UTC. A
few examples will help to clarify.
>
Example 1. UTC time= 01:00:00. Local time= 18:01:10 will set the local
time to 18:00:00.
>
Example 2. UTC time= 01:00:00. Local time= 18:25:30 will set the local
time to 18:30:00.
>
Example 3. UTC time= 01:12:10. Local time= 18:50:30 will set the local
time to 18:42:10.
-
During Holdover Event
-
The date/time continues to increment normally.
During Holdover Alarm
-
- The date/time continues to increment normally.
Example to set date without changing time or mode:
ED-DAT:::<ctag>::2000-08-13;
Example to change to local time:
ED-DAT:::<ctag>::2000-08-13,07-00-00:MODE=LOCAL;
Example to change from local to UTC time:
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
TimeSource 3000
097-72000-02 Issue 6: October 2003
S
S
S
S
S
TL1 Reference

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TimeSource 3000 and is the answer not in the manual?

Table of Contents