Boiler dimension, width
Boiler dimension, height
Boiler dimension, depth
Approx. net weight
Ready for operation
weight approx.
Technical data – G20 power/loading G20
Nominal heat output
range P at 80/60 °C
Nominal heat output
range P at 60/40 °C
Nominal heat output
range P at 50/30 °C
Nominal heat output
range P at 40/30 °C
Maximum heat input,
heating side
Minimum heat input
Technical data – Heating
Max. flow temperature
adjustment range (default
setting: 80 °C)
Permissible total over-
pressure
Floor-standing boiler ca-
pacity (without connec-
tion piece)
Circulation water volume
(with reference to
ΔT= 20 K)
Pressure loss (with refer-
ence to ΔT= 20 K)
Condensate volume at
heating mode 40/30 °C
Heating standby losses
per day (heating 70 °C)
Technical data – Electrics
Rated voltage
Permissible connected
voltage
Built-in fuse (slow-blow,
H or D)
Max. electrical power
consumption
Standby electrical power
consumption
Level of protection
Unit protection class
Test symbol/registration
no.
0020149561_01 ecoCRAFT exclusive Installation and maintenance instructions
VKK GB
VKK GB
806/3-E R1
1206/3-E R1
695 mm
695 mm
1,285 mm
1,285 mm
1,240 mm
1,240 mm
200 kg
220 kg
210 kg
235 kg
VKK GB
VKK GB
806/3-E R1
1206/3-E R1
13.6
21.3
... 78.2 kW
... 113.4 kW
14.1
22.1
... 80.4 kW
... 116.5 kW
14.4
22.7
... 82.4 kW
... 119.4 kW
14.7
23.1
... 84.1 kW
... 121.8 kW
80.0 kW
115.9 kW
14.0 kW
22.0 kW
VKK GB
VKK GB
806/3-E R1
1206/3-E R1
35 ... 85 ℃
35 ... 85 ℃
0.6 MPa
0.6 MPa
(6.0 bar)
(6.0 bar)
5.74 l
8.07 l
3.44 m³/h
4.99 m³/h
0.008 MPa
0.0085 MPa
(0.080 bar)
(0.0850 bar)
13 l/h
20 l/h
<0.4%
<0.4%
VKK GB
VKK GB
806/3-E R1
1206/3-E R1
230 V/50 Hz
230 V/50 Hz
190 ... 253 V
190 ... 253 V
4 A
4 A
260 W
260 W
8 W
8 W
IP 20
IP 20
Class I
Class I
CE-
CE-
0063BS3740
0063BS3740
VKK GB
VKK GB
1606/3-E R1
2006/3-E R1
695 mm
695 mm
1,285 mm
1,285 mm
1,240 mm
1,550 mm
235 kg
275 kg
255 kg
300 kg
VKK GB
VKK GB
1606/3-E R1
2006/3-E R1
26.2
43.1
... 156.5 kW
... 196.8 kW
27.1
44.2
... 160.8 kW
... 201.0 kW
27.8
45.3
... 164.8 kW
... 206.0 kW
28.4
46.2
... 168.2 kW
... 210.2 kW
160.0 kW
200.0 kW
27.0 kW
44.0 kW
VKK GB
VKK GB
1606/3-E R1
2006/3-E R1
35 ... 85 ℃
35 ... 85 ℃
0.6 MPa
0.6 MPa
(6.0 bar)
(6.0 bar)
10.4 l
12.73 l
6.88 m³/h
8.60 m³/h
0.009 MPa
0.0095 MPa
(0.090 bar)
(0.0950 bar)
27 l/h
34 l/h
<0.4%
<0.4%
VKK GB
VKK GB
1606/3-E R1
2006/3-E R1
230 V/50 Hz
190 ... 253 V
190 ... 253 V
4 A
4 A
320 W
320 W
8 W
8 W
IP 20
IP 20
Class I
Class I
CE-
CE-
0063BS3740
0063BS3740
Appendix
VKK GB
VKK GB
2406/3-E R1
2806/3-E R1
695 mm
695 mm
1,285 mm
1,285 mm
1,550 mm
1,550 mm
295 kg
310 kg
320 kg
340 kg
VKK GB
VKK GB
2406/3-E R1
2806/3-E R1
47.0
51.0
... 236.2 kW
... 275.5 kW
48.2
52.3
... 241.2 kW
... 281.4 kW
49.1
53.6
... 247.2 kW
... 288.4 kW
50.4
54.7
... 252.2 kW
... 294.3 kW
240.0 kW
280.0 kW
48.0 kW
52.0 kW
VKK GB
VKK GB
2406/3-E R1
2806/3-E R1
35 ... 85 ℃
35 ... 85 ℃
0.6 MPa
0.6 MPa
(6.0 bar)
(6.0 bar)
15.05 l
17.37 l
10.33 m³/h
12.05 m³/h
0.01 MPa
0.0105 MPa
(0.10 bar)
(0.1050 bar)
40 l/h
47 l/h
<0.4%
<0.4%
VKK GB
VKK GB
2406/3-E R1
2806/3-E R1
230 V/50 Hz
230 V/50 Hz
190 ... 253 V
190 ... 253 V
4 A
4 A
320 W
320 W
8 W
8 W
IP 20
IP 20
Class I
Class I
CE-
CE-
0063BS3740
0063BS3740