Vaillant geoTHERM exclusive Operating Manual
Vaillant geoTHERM exclusive Operating Manual

Vaillant geoTHERM exclusive Operating Manual

Heat pump with integrated domestic hot water cylinder and additional cooling function
Hide thumbs Also See for geoTHERM exclusive:
Table of Contents

Advertisement

For the owner
Operating manual
geoTHERM exclusive
Heat pump with integrated domestic hot water cylinder
VWS
and additional cooling function
GB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the geoTHERM exclusive and is the answer not in the manual?

Questions and answers

Summary of Contents for Vaillant geoTHERM exclusive

  • Page 1 For the owner Operating manual geoTHERM exclusive Heat pump with integrated domestic hot water cylinder and additional cooling function...
  • Page 2: Table Of Contents

    Equipment and functional description ... Principle of operation ..........9 Mode of operation of the coolant circuit .... 9 Automatic auxiliary functions ........ 10 Design of the geoTHERM exclusive heatpump Operation ............13 Familiarising yourself with and operating the controller ..............13 5.1.1...
  • Page 3: General Information

    Data badge An identification plate is attached to the baseplate on the inside of the geoTHERM exclusive heat pump. The type designation is located at the top of the front clad- ding (see also Fig. 4.3, Item 1). In Chapter 7.2 of the Ap-...
  • Page 4: Symbols Used

    Avoid contact with the skin and eyes. Note! R 407 C presents no danger in normal use and under normal conditions. With improper use, however, it can cause inju- ry and damage. Operating Manual geoTHERM exclusive VWS 0020071929_00...
  • Page 5: Prohibition On Alterations

    Prohibition on alterations operation Danger!Inappropriate alterations can cause injuries! Vaillant geoTHERM exclusive heat pumps are built using Under no circumstances should you at- state-of-the-art technology and according to standard tempt to make changes or alterations to safety regulations and must be installed by a qualified...
  • Page 6: Requirements Of The Installation Site

    In contrast to heaters that operate using fossil fuels, no Caution! complex maintenance work is necessary for the Vaillant Risk of damage from brine escaping from geoTHERM exclusive heat pump. leaks in the system.
  • Page 7: Accumulation Of Condensate (Condensation Water)

    6 % per annum. under the heat pump. In small amounts, accumulating condensate should not be seen as a fault in the heat pump. Operating Manual geoTHERM exclusive VWS 0020071929_00...
  • Page 8: Recycling And Disposal

    — Set the thermostatic valves: 3.6.3 Coolant You can adjust the room temperature to suit your in- The Vaillant heat pump is filled with R 407 C coolant. dividual requirements and ensure effective operation of your heating installation using the thermostatic Danger!
  • Page 9: Equipment And Functional Description 4

    Condenser Coolant circuit Expansion valve Compressor Evaporator The Vaillant geoTHERM exclusive heat pump uses geo- thermal energy as its heat source. Heat source circuit Mixer valve 1/4 Electrical energy Cooling heat exchanger 3/4 Environmental energy 4/4 Heating energy...
  • Page 10: Automatic Auxiliary Functions

    The heat pump switches on again when the brine pres- sure rises above 0.4 bar gauge pressure. geoTHERM exclusive heat pumps by Vaillant are If the brine pressure drops below 0.6 bar on the pres- equipped with an auxiliary cooling function that ensures...
  • Page 11: Design Of The Geotherm Exclusive Heatpump

    Design of the geoTHERM exclusive heat pump A domestic hot water cylinder with a capacity of 175 li- tres is integrated into the Vaillant geoTHERM exclusive heat pump. The heat pump is available in three versions, which differ mainly in their output.
  • Page 12 3 Heat source to the heat pump 4 Heat source from the heat pump 5 Heating return 6 Heating flow 7 Handle trough 8 Handle trough/cable grommet, electrical connection 9 Ventilation, heating flow to domestic hot water cylinder Operating Manual geoTHERM exclusive VWS 0020071929_00...
  • Page 13: Operation 5

    You can access the next menu by turning setting value to be accepted. dial. The numbers make it easier to find individual menus during programming. • Repeat this sequence until all the settings have been made. Operating Manual geoTHERM exclusive VWS 0020071929_00...
  • Page 14: Setting Menus And Parameters

    The controller on the operating panel of the heat pump is used to programme the mixer circuits. In order to op- erate under comfortable conditions you can connect the remote control units VR 90 for the first eight heating circuits. Operating Manual geoTHERM exclusive VWS 0020071929_00...
  • Page 15: Energy Balance Control

    When you reset the control system to the default settings, specific system settings can be deleted and the system can sut down. The system does not suf- This symbol points you to these energy saving tips. fer damage. Operating Manual geoTHERM exclusive VWS 0020071929_00...
  • Page 16: Flow Diagram

    >Select day of the week Room Temp. setpoint 12 ºC >Select day of the week >Set starting day >Select day of the week Code level only for expert technicians Fig. 5.3 Displays in the User level Operating Manual geoTHERM exclusive VWS 0020071929_00...
  • Page 17: User Level Displays

    The symbol indicates that the heat pump is in cooling operation. Under the symbol the actual heating flow temperature is displayed (in the example 20 °C). Table 5.1 Settable parameters in the operator level Operating Manual geoTHERM exclusive VWS 0020071929_00...
  • Page 18 CH return too high Under critical operating conditions a warning message is displayed in both lower display lines. These lines are empty when the operating conditions are normal. Table 5.1 Adjustable parameters at the operator level (contd.) Operating Manual geoTHERM exclusive VWS 0020071929_00...
  • Page 19 Off: The heating circuit is off, provided that the frost protection function (depending on the external tem- perature) is not activated. Note: Additional heating circuits are displayed, depending on the system configuration. Table 5.1 Adjustable parameters at the operator level (contd.) Operating Manual geoTHERM exclusive VWS 0020071929_00...
  • Page 20 1st February 2002 energy conservation regulation) the room temperature reduction can be dispensed with owing to low heat losses. The desired set-back temperature must be set in menu 2. Table 5.1 Adjustable parameters at the operator level (contd.) Operating Manual geoTHERM exclusive VWS 0020071929_00...
  • Page 21 The operating times of the circulation pump can thus be optimally matched to the actual need. Consult your expert technician about doing this. Table 5.1 Adjustable parameters at the operator level (contd.) Operating Manual geoTHERM exclusive VWS 0020071929_00...
  • Page 22 Caution! Do not try to access the code level by mak- ing arbitrary entries in the code level. Unintentional modification of the system-specific parameters can cause malfunctions or damage to the heat pump. Table 5.1 Adjustable parameters at the operator level (contd.) Operating Manual geoTHERM exclusive VWS 0020071929_00...
  • Page 23: Special Functions

    "Auto" or "ECO" is set. One-time charging: 16.02.08 9:35 This function allows you to charge the hot water cylinder once, re- gardless of the current time program. one-time DHW tank loading enabled Table 5.2 Special functions Operating Manual geoTHERM exclusive VWS 0020071929_00...
  • Page 24 The system does not suffer damage. Time programme NO/YES Everything NO/YES Press both dials for at least 5 seconds to request the menu default >Settable values setting. Table 5.3 Re-establishing the default setting Operating Manual geoTHERM exclusive VWS 0020071929_00...
  • Page 25: Starting Up The Heat Pump

    5.4 to 5.7. Only genuine Vaillant spare parts may be used for in- Do not attempt to remove the source of spections, maintenance and repair work to ensure the the malfunction yourself.
  • Page 26: Activating Emergency Mode

    Table 5.5 Warning messages, no shutdown Coolant pressure outside the range If the error occurs twice in a row the heat pump cannot be started until after 60 min. at the earliest. Table 5.6 Temporary malfunctions Operating Manual geoTHERM exclusive VWS 0020071929_00...
  • Page 27: Fault-Induced Shutdown

    Frost protection heat source possible monitoring source outlet Error 20 has occurred three times in a row Frost protection heat source possible monitoring source outlet Error 22 has occurred three times in a Table 5.7 Error shutdown Operating Manual geoTHERM exclusive VWS 0020071929_00...
  • Page 28: Warranty And Customer Service

    6 Warranty and customer service Warranty and customer service Vaillant warranty Vaillant provide a full parts and labour warranty for this appliance. The appliance must be installed by a suitably competent person in accordance with the Gas Safety (Installation and Use) Regulations 1998, and the manufacturer’s in- structions.
  • Page 29: Appendix 7

    IP 20 Hydraulic connections - Heating circuit flow and return G 1 1/4", Ø 28 - Heat source flow and return G 1 1/4", Ø 28 - Cold/hot water R 3/4" Table 7.1 Technical data Operating Manual geoTHERM exclusive VWS 0020071929_00...
  • Page 30 VL = 18 °C and heating return RL = 22 °C! Sound output Conforms to safety regulations CE mark Low Voltage Directive 73/23/EWG EMC Directive 89/336/EWG EN 60335 ISO 5149 Table 7.1 Technical data (cont.) Operating Manual geoTHERM exclusive VWS 0020071929_00...
  • Page 31: Identification Plate

    Explanation of the symbols on the identification plate An identification plate is attached to the baseplate on the inside of the geoTHERM exclusive heat pump. The Rated voltage - compressor type designation is located at the top of the front clad- ding (see Fig.

Table of Contents