Overview Of Diagnostics Codes - Vaillant ecoCRAFT exclusive VKK GB 1206/3-E R1 Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

No.
Procedure
6
Check the entire gas route for leaks
7
Carrying out a chimney draught meas-
urement
8
CO₂ measurement
9
If the CO₂ is not within the tolerance:
10
After setting the CO₂, activate chimney
sweep mode again and measure the
CO₂ content
11
CO measurement (target value <
80 ppm)
12
Check the condensate tray, condens-
ate siphon and condensate discharge
for leak-tightness
13
Switching off the product and switching
it back on again
14
Programme the heating controller with
the customer and check that the hot
water/heating are working correctly
15
Stick sticker 835593 "Read the oper-
ating instructions" on the front of the
product, in the language spoken by the
end user
C

Overview of diagnostics codes

Note
Since the code table is used for various products, some codes may not be visible for the product in question.
Code Parameter
D.00
Heating partial load, adjustable val-
ues in kW
D.01
Heating pump overrun time
D.02
Max. burner anti-cycling time heating
at 20 °C flow temperature
D.04
Measured value for the cylinder tem-
perature in °C
D.05
Flow temperature target value (or
return target value) in °C
D.07
Target cylinder temperature
D.08
Room thermostat at terminal 3-4
0020149561_01 ecoCRAFT exclusive Installation and maintenance instructions
Comment
Leak-detection spray or leak detector
(a leak detector is especially recom-
mended for checking the burner seals
for gas tightness)
If required, tighten the burner seal
(tightening torque: 12 Nm)
The maximum draught must not ex-
ceed 20 Pa. If the draught is too great,
the chimney draught must be restricted
using suitable measures.
Target value for nominal heat loading:
Only carry out the measurement after
five minutes of normal operation
9.3 vol.% ±0.2 with natural gas H
Target value for the minimum heat
load:
9.0 vol.% ±0.2 with natural gas H
Adjust the CO₂ and then take the
measurement again
Target value for nominal heat loading:
9.3 vol.% ±0.2 with natural gas H
Target value for the minimum heat
load:
9.0 vol.% ±0.2 with natural gas H
Carry out a visual check or also use a
CO measuring instrument to go along
the sealing points.
End the maximum output operation
Handing over the operating instructions
to the customer
Values or explanations
Maximum value = nominal heat output
2 ... 60 min
2 ... 60 min
If a domestic hot water cylinder with sensor is connected
Current target value, calculated from the set value, con-
troller, control type, etc.
(15 °C = frost protection, 40 °C up to D.20 (max. 70 °C))
0 = Open, no heating mode; 1 = Closed, heating mode
Appendix
Required tool
Leak detector
Measuring instrument for chimney
draught
CO₂-measuring instrument
CO₂-measuring instrument
CO measuring instrument
Default set-
Own setting
ting
Automatic
heating par-
tial load
5 min
20 min
Not
adjustable
31