Fault Analysis Mode

If a fault occurs, the FAULT or MAINS indicators flash and the codepad beeps once every min.
If the AC MAINS supply fails, the MAINS indicator flashes until the AC MAINS supply is
restored. Pressing the [#] button once acknowledges the fault and stops the codepad from
beeping once every min.
How to Determine the Type of System Fault
To determine which system fault occurred, enter Fault Analysis Mode by following the steps
below:
1.
2.
3.
Fault Indicators
Zone
Indicator
1
2
3
4
5
2017.09 | 04 | F.01U.298.028
Enter the zone number (1 to 8 / 16), followed by the [*] button (for example, [1*] = Zone
1, [2*]= Zone 2). Each zone to be isolated has a corresponding zone indicator that
flashes. If you selected an incorrect zone to be isolated, enter the incorrect zone number
again followed by the[*] button. Repeat Step 2 if more than one zone is to be isolated
until all zones to be isolated are selected.
Press the [#] button after all selected zones are isolated. Two beeps sound and the
system returns to the disarmed state.
Hold down the [5] key until two beeps sound. The STAY and AWAY indicators flash in
unison. A zone indicator displays the type of fault that occurred (for example, Zone 1 =
System Fault). Refer to Fault Indicators, page 18 for the list of possible system faults.
To further determine the type of fault condition, press the key that corresponds to the
zone indicator displayed. For example, if Zone 1 displayed System Fault, press the [1] key
to display which system fault occurred.
To exit Fault Analysis Mode and return to the disarmed state, press the [#] key. The
FAULT indicator continues to display and the codepad stops sounding once a min.
Fault Description
System Fault
RF Low Battery
(Solution 2000
N.A.)
Zone Tamper Alarm
Sensor Watch Fault
RF Sensor Missing
(Solution 2000
N.A.)
Press
Zone
Button
Indicator
1
1
2
3
4
5
7
8
9 to 16
2
1 to 16
3
1 to 16
4
1 to 16
5
1 to 16
User's Guide
Fault Condition
Battery Fail
Date and Time
RF Receiver Fail
Output 1 to 3 Fail
Telephone Line Fail
Power Supply Fail
Onboard Tamper
RF Repeaters 1 to 8 Fail (Solution
2000 N.A.)
Zones 1 to 16 RF Low Battery
Zones 1 to 16 Tamper Alarm
Zones 1 to 16 Sensor Watch Fail
Zones 1 to 16 RF Sensor Watch Fail