Lenovo ThinkStation P720 Hardware Maintenance Manual page 85

Hide thumbs Also See for ThinkStation P720:
Table of Contents

Advertisement

b. Select Advanced ➙ Intel(R) VMD technology and press Enter.
c. Select each menu item and press Enter. Then, select Enabled and press Enter.
d. Select an occupied M.2 solid-state drive slot as you need and press Enter. Then, select VMD and
press Enter.
e. To save settings and exit the Setup Utility program, press F10 or Fn+F10 (depending on the
keyboard settings), select Yes in the window displayed, and press Enter.
2. Start the Setup Utility program again. See "Starting the Setup Utility program" on page 67.
3. Select Advanced ➙ Intel Virtual RAID on CPU and press Enter.
4. Select All Intel VMD Controllers and press Enter.
5. Select Create Volumes and press Enter.
6. Select and configure the options one by one.
a. Name: You can use the default name Volume0 or type a preferred name for the RAID volume.
b. RAID Level: You can set the RAID level to one of the following:
• RAID0
• RAID1
• RAID10
• RAID5
Note: Some of the RAID levels might not be displayed because the number of installed M.2 solid-
state drives and the model of the upgrade key module vary.
c. Select Disks: Select an M.2 solid-state drive and press Enter. Then, select X and press Enter to add
it to a group.
d. Stripe Size (if applicable): Select a stripe size and press Enter.
e. Capacity: Customize the capacity of the RAID volume. The default RAID volume is the largest value.
7. Select Create Volume and press Enter to create a RAID volume.
8. To save settings and exit the Setup Utility program, press F10 or Fn+F10 (depending on the keyboard
settings), select Yes in the window displayed, and press Enter.
Viewing the information about a RAID volume
To view the information about a RAID volume, do the following:
1. Start the Setup Utility program. See "Starting the Setup Utility program" on page 67.
2. Select Advanced ➙ Intel Virtual RAID on CPU and press Enter.
3. Select RAID Volumes and press Enter.
4. Select a RAID volume and press Enter to view the detailed information.
Deleting a RAID volume
Attention: All the existing data stored on the selected drives will be erased after you delete RAID volumes.
To delete a RAID volume, do the following:
1. Start the Setup Utility program. See "Starting the Setup Utility program" on page 67.
2. Select Advanced ➙ Intel Virtual RAID on CPU and press Enter.
3. Select Intel VROC Mananged Volumes and press Enter.
4. Under Volume Actions, select Delete and press Enter.
5. When prompted, select Yes and press Enter to confirm the deletion of the selected RAID volume.
.
Chapter 6
Advanced configuration
79

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

30ba30bb30bu

Table of Contents