Miscellaneous - NEC Express 5800 Series User Manual

Bmc configuration
Hide thumbs Also See for Express 5800 Series:
Table of Contents

Advertisement

BMC Configuration User's Guide
4.2.14

Miscellaneous

This screen displays and sets the various functions of BMC.
Item
SEL
Behavior
when
SEL
repository is full
Power Restore Delay
AC-Link
Delay Time
PEF
Platform Event Filter
Management Software
ESMPRO Management
Description
SEL setting
Select the Behavior when SEL repository is full. *1
Stop logging SEL
: SEL is not recorded any more.
Clear all SEL
: Delete all SEL and record SEL newly.
Overwrite oldest SEL
: Old SEL is overwritten with new SEL.
Power Restore Delay setting
Select the AC-Link setting.
Stay Off
: DC is not turned on.
Last State
: It becomes the same as time when AC was turned off.
Power On
: DC on always.
Set the value or specify the Random. The range is from
"Minimum value" to "600"[Sec], *3
PEF setting
Select Enable/Disable of Platform Event Filter. *4
Management Software setting
Select Enable/Disable of ESMPRO Management. *5
Default Value
Stop logging SEL
Last State *2
Minimum value
Enable
Current value

Advertisement

Table of Contents
loading

Table of Contents