Note on expansion of VNIC System No.
CB2000
When you execute LPAR migration in Concurrent Maintenance mode between
HVM firmware 59-11/79-11 or earlier and 59-21/79-21 or higher, and the
VNIC System No. set for the HVM firmware 59-21/79-21 or higher is 129 or
greater, you cannot execute LPAR migration in Concurrent Maintenance. Check
the combination which you can execute LPAR migration in Concurrent
Maintenance in the following table.
Table 2-109 LPAR migration on HVM on CB 2000 standard server blade
Source
HVM firmware version
59-11 or earlier
59-21 or higher
Table 2-110 LPAR migration on HVM on CB 2000 high-performance
server blade
Source
HVM firmware version
79-11 or earlier
79-21 or higher
CB500
When you execute LPAR migration in Shutdown mode between HVM firmware
01-30 or earlier and 01-40 or higher, and the VNIC System No. set for the
HVM firmware 01-40 or higher is 129 or greater, you cannot execute LPAR
migration in Shutdown mode. Check the combination which you can execute
LPAR migration in Shutdown mode in the following table.
Table 2-111 LPAR migration on HVM on CB 500 server blade
Source
HVM firmware version
01-30 or earlier
01-40 or higher
HVM Navigator User's Guide - Migration
Destination
59-11 or earlier
VNIC System No.
128 or smaller
128 or smaller
128 or smaller
129 or greater
Destination
79-11 or earlier
VNIC System No.
128 or smaller
128 or smaller
128 or smaller
129 or greater
Destination
VNIC System No.
128 or smaller
128 or smaller
129 or greater
Usage environments
Concurrent Maintenance
HVM firmware version
59-21 or higher
128 or smaller
Yes
Yes
Yes
Yes
No
Yes
HVM firmware version
79-21 or higher
128 or smaller
Yes
Yes
Yes
Yes
No
Yes
HVM firmware version
01-30 or earlier
128 or smaller
128 or smaller
Yes
Yes
Yes
Yes
No
Yes
129 or greater
No
Yes
Yes
129 or greater
No
Yes
Yes
01-40 or higher
129 or greater
No
Yes
Yes
2-63