8. THE BEHAVIOR OF THE SYSTEM IN COMPATIBILITY
MODE FOR GRADE 2
The system operates in accordance with the EN 50131 standard requirements for
Grade 2, i.e.:
zones status is available only after user code has been entered
information about alarms is available only after user code has been entered
information about alarms memory is available only after user code has been
entered
information about failures is available only after user code has been entered
information about failures memory is available only after user code has been
entered
arming requires authorization
prior to arming, the control panel checks circumstances that may prevent
arming
the codes in the system must be at least 5 characters
after entering an invalid code three times, all keypads in the system will be
blocked for 90 seconds.
9. CHANGE HISTORY
Date / Version / Firmware
22.09.2014 / i1.0 / 2.0RC6
26.11.2014 / i1.1 / 2.0RC7
18.06.2015 / i1.2 / 2.1.0
03.09.2015 / i1.3 / 2.2.0
08.10.2015 / i1.4 / 2.2.0
09.11.2015 / i1.5 / 2.3.1
08.01.2016 / i1.6 / 2.3.7
CPX200NB ALARM CONTROL UNIT – USER MANUAL
EN
Description
First version of the manual
Small changes
Added: duress code, stay/away, function keys
Added new EVENT class parameters, which are used
by GETUSERSMS and SETUSERSMS commands
Updated information about stay/away mode
Updated information about stay/away mode
Updated information about testing the outputs
30 / 30