8. THE BEHAVIOR OF THE SYSTEM IN COMPATIBILITY
MODE FOR GRADE 2
The system operates in accordance with the EN 50131 standard requirements for
Grade 2, i.e.:
 zones status is available only after user code has been entered
 information about alarms is available only after user code has been entered
 information about alarms memory is available only after user code has been
entered
 information about failures is available only after user code has been entered
 information about failures memory is available only after user code has been
entered
 arming requires authorization
 prior to arming, the control panel checks circumstances that may prevent
arming
 the codes in the system must be at least 5 characters
 after entering an invalid code three times, all keypads in the system will be
blocked for 90 seconds.
9. CHANGE HISTORY
Date / Version / Firmware
22.09.2014 / i1.0 / 2.0RC6
26.11.2014 / i1.1 / 2.0RC7
18.06.2015 / i1.2 / 2.1.0
03.09.2015 / i1.3 / 2.2.0
08.10.2015 / i1.4 / 2.2.0
09.11.2015 / i1.5 / 2.3.1
08.01.2016 / i1.6 / 2.3.7
CPX200NB ALARM CONTROL UNIT – USER MANUAL
EN
Description
First version of the manual
Small changes
Added: duress code, stay/away, function keys
Added new EVENT class parameters, which are used
by GETUSERSMS and SETUSERSMS commands
Updated information about stay/away mode
Updated information about stay/away mode
Updated information about testing the outputs
30 / 30

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents