Summary of Contents for Beckman Coulter PA 800 plus
Page 1
Pre-Installation Guide PA 800 plus Pharmaceutical Analysis System 32 Karat™ Software Version 9.1 and PA 800 plus Software Version 1.1 A51977AC February 2011 Beckman Coulter, Inc. 250 S. Kraemer Blvd. Brea, CA 92821...
Page 3
Revision History Second Revision, A51977AC, February 2011 32 Karat Software version 9.1 patch PA 800 plus Software version 1.1 patch PA 800 plus Firmware version 9.2 Numerous syntax and grammatical edits First Revision, A51977AB, December 2009 Revised corporate address. Initial Issue, A51977AA, April 2009 32 Karat Software version 9.1...
Page 5
Safety Notices Symbols and Labels Introduction The following is a description of symbols and labels used on the Beckman Coulter PA 800 plus Pharmaceutical Analysis System or shown in this manual. WARNING If the equipment is used in a manner not specified by Beckman Coulter, Inc., the protection provided by the instrument may be impaired.
Page 6
THIS PRODUCT CONFORMS TO APPLICABLE REQUIREMENTS OF 21 CFR 1040 AT THE DATE OF MANUFACTURE. MANUFACTURED: 726024-C A016350L.EPS Sharp Object Label A label reading “CAUTION SHARP OBJECTS” is found on the PA 800 plus. CAUTION SHARP OBJECTS A16558-AA A016351L.EPS A51977AC...
Page 7
For Beckman Coulter products bearing this label, please contact your dealer or local Beckman Coulter office for details on the take back program that facilitates the proper collection, treatment, recovery, recycling, and safe disposal of this device.
Page 8
Safety Notices Symbols and Labels Restriction of Hazardous Substances (RoHS) Labels These labels and materials declaration table (the Table of Hazardous Substance's Name and Concentration) are to meet People's Republic of China Electronic Industry Standard SJ/T11364-2006 "Marking for Control of Pollution Caused by Electronic Information Products" requirements. RoHS Caution Label This logo indicates that this electronic information product contains certain toxic or hazardous elements, and can be used safely during its environmental protection use period.
Page 9
Safety Notices Symbols and Labels Alerts for Warning, Caution, Important, and Note WARNING WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. The warning can be used to indicate the possibility of erroneous data that could result in an incorrect diagnosis (does not apply to all products).
Page 10
Safety Notices Symbols and Labels A51977AC...
Page 11
Introduction, xiii General Description, xiii Pre-Installation, 1-1 CHAPTER 1: Preparation Check List, 1-1 Technical Support, 1-1 Pre-Installation Check List, 1-2 PA 800 plus , 1-2 Computer, 1-2 Detectors, 1-2 Options, 1-2 Site Requirements, 2-1 CHAPTER 2: Tabletop Space, 2-1 Space...
Page 12
Contents PA 800 plus System Training, 4-1 CHAPTER 4: Pre-Training Requirements, 4-1 Additional Training, 4-1...
Page 13
For your convenience, a pre-installation checklist is included to help you prepare for the installation. NOTE This manual applies to instruments running PA 800 plus software and also to instruments running field- upgraded PA 800 Enhanced software. A51977AC xiii...
Page 14
Introduction General Description A51977AC...
Page 15
• Training prerequisites met Technical Support If you encounter a problem that is not discussed in this guide, and you need technical support, contact your local dealer, the provider of this product, or contact Beckman Coulter directly by using the information below. NOTE Whenever you call your local dealer or Beckman Coulter, be sure to have your registration material, instrument serial number, and software version number available.
Page 16
Pre-Installation Check List The following is a list of requirements and items necessary for installation of the PA 800 plus. Use this list to check off the requirements and items you have and other items as you receive them. To ensure a successful installation, please verify that you have these items prior to scheduling the installation with your local office.
Page 17
CHAPTER 2 Site Requirements Tabletop Space The PA 800 plus System is made up of the PA 800 plus unit and one each of the following: • IBM PC Tower • 22” Monitor • Keyboard • Mouse Figure 2.1 PA 800 plus Dimensions...
Page 18
Site Requirements Tabletop Space Space Requirements The instrument dimensions are shown in Figure 2.1. In addition to space for the instrument itself, allow additional space for the computer and printer (if any). Figure 2.2 illustrates the recommended system setup. Ventilation Requirements Adequate space must be provided around instrument for ventilation and access to the communication’s connector.
Page 19
Tabletop Space Electrical Requirements The PA 800 plus is shipped with a power cord suitable for North America (nominal 120 VAC, 60 Hz) installations. A power cord suitable for non-North America installations will be provided by Beckman Coulter. The instrument requires one grounded electrical outlet.
Page 20
Site Requirements Tabletop Space A51977AC...
Page 21
CHAPTER 3 Specifications PA 800 plus System Use this information to prepare the environment where the system is to be located. Item Description Weight (PA 800 plus) 188 lbs (85.3 kg) Firmware Version 9.0 or Higher Power Requirements Supply voltage must not exceed 10% of nominal PA 800 plus 100-240VAC, 5.0A, 50/60Hz;...
Page 22
Any Microsoft Windows XP-compatible printer Operating System Microsoft Windows XP Pro with Service Pack 2 Software 32 Karat version 9.1 and PA 800 plus version 1.1 IMPORTANT Users must have Administrator or Power user permission on the local workstation. IMPORTANT Install 32 Karat software in the C:\32Karat folder.
Page 23
Specifications PA 800 plus System PDA Detector Specification Type Description Wavelength Range 190 to 600 nm Detector 256 Element Diode Array UV Source Deuterium Lamp; 30 W; pre-aligned Wavelength Accuracy 2 nm Bandwidth 6 nm minimum (Absorbance Averaging) Analog Output Output 1 is Data Channel 1 and Output 2 is Data Channel 2;...
Page 24
Specifications PA 800 plus System Specification Type Description Laser 3 mW 635 nm Solid State External Laser 3 mW 488 nm Solid State Laser Analog Outputs Output 1 is Data Channel 1 and Output 2 is Data Channel 2; Full scale output is 1.0 AU/V (software selectable multipliers of 1.0,...
Page 25
PA 800 plus System Training Pre-Training Requirements After the system has been installed, a Beckman Coulter Field Engineer will train up to two operators in basic instrument operation. Successful implementation of the installation is dependent upon the training environment. To ensure a focused and optimized training session, follow these guidelines: 1.
Page 26
PA 800 plus System Training Additional Training A51977AC...
Need help?
Do you have a question about the PA 800 plus and is the answer not in the manual?
Questions and answers