24
Interior Masonry Chimney Conversions (top vent configuration only)
•
Follow the requirements and use the equipment listed in the illustration below to install this appliance
into an interior masonry chimney.
•
Maximum vertical rise is 40'
•
Minimum vertical rise is 10'
•
See the chart on page 20 for determining the correct restrictor position.
NOTE: these restrictor positions are based upon lab tests. The ideal restrictor position may vary
slightly.
Freestanding Masonry Chimney
Standard Masonry Fireplace
The entire chimney system must
be air-tight. Seal the connector
cover and inspect the chimney.
Make sure the coaxial pipe
maintains a 1" (25mm) clearance to
any combustible. The vent must be
sealed air-tight.
© Travis Industries
Installation
The entire chimney system must be
air-tight. Make sure to seal the
flashing, clean-out, and thimble
connection, and to inspect the
chimney.
Make sure the coaxial pipe
maintains a 1" (25mm) clearance to
any combustible. The vent must be
sealed air-tight.
#990 90° Elbow
Co-Axial Straight
Lengths
(for qualified installers only)
4" (102mm) Dia. Flex Line
(UL 1777 Gas Liner)
Connector with Cover
(included in #934 Masonry
Conversion Kit)
#991 High Wind
Termination
Flashing (included in
#934 Masonry
Conversion Kit)
4" (102mm) Dia. Flex Line
(UL 1777 Gas Liner)
Connector (included in #934
Masonry Conversion Kit)
secured and sealed to
block-off plate.
1/3/18 - 1444
#991 High Wind
Termination
Flashing (included in
#934 Masonry
Conversion Kit
Cypress GSR2