Failure to inspect and maintain the stove may lead to improper combustion and a potentially
dangerous situation. We recommend the following procedures be done by a qualified technician.
1. Turn the pilot flame to continuous. It should touch approximately 3/8" of the top of the flame sensor.
If it does not, contact your dealer for service.
2. Shut off gas to the stove and let it cool for 15 minutes. Remove the glass (see page 27).
3. Remove the log set (NOTE: The logs are very fragile - see page 29). If severely deteriorated,
replace. Check the logs for sooting. A small amount of soot along the bottom of the logs is normal.
If excessive sooting is found, the stove will require adjustment. Contact your dealer.
4. Inspect the burner and remove any debris.
Make sure the burner is not warped, cracked, or damaged.
Check the firebox and area around the pilot to make sure there is no warping or damage.
If any problem is found, discontinue use and contact your dealer for service.
5. Install the log set. Clean and replace the glass. If the glass is damaged, replace. Make sure the
gasket along the perimeter of the glass contacts the face of the firebox and forms an air-tight seal. If
it does not, re-align or replace the gasket to insure an air-tight seal.
6. Inspect the area behind the access door. Clean if necessary. Check the gas control valve and the
gas lines. If damage is found, discontinue use and contact your dealer for service. Clean the air
channels, ducts, and blower (if applicable).
7. Start the main burner. After 15 minutes the flames should be orange/yellow and not touch the top of
the firebox. If the pilot or main burners do not burn correctly, contact your dealer for service. Monitor
blower operation.
8. Remove any debris or vegetation near the vent termination. Contact your dealer if any sooting or
deterioration is found near the vent termination.