Remove and Replace the Drive
16 If the LEDs are displaying properly, you can vary on the drive. From the
Drives screen:
a Select the newly installed drive.
b Click the Vary On button.
c Click Cancel.
17 The library may update the drive sled firmware. Wait a few minutes to see if
a dialog box appears. If this happens, wait until it is complete before
continuing. The drive sled firmware update will take approximately 5
minutes.
18 Go to the rear of the module and observe the drive status LEDs and wait for
the following conditions to occur:
• Green LED 1 - solid green indicating port connectivity to either the
FC I/O blade or the customer FC switch
• Amber LED - off
• Blue LED - blinks one time per 10 seconds
• Green LED 2 - blinks at the same cadence as the other green LEDs on
the other drives in the module
19 Close the access doors.
20 Close the ticket that was generated for the failed drive.
Quantum Scalar i6000: Drive Replacement
Green Port LED 1
6-67999-01 Rev A
October 2013
Blue LED
Amber LED
Green LED 2
7