Quantum Scalar i6000 Replacement page 10

Drive
Hide thumbs Also See for Scalar i6000:

Advertisement

Quantum Scalar i6000: Drive Replacement
6-67999-01 Rev A
October 2013
10
Note: On the back of the drive, the Green LED 2 will flash rapidly while
the firmware update is in progress.
10 The library updates the firmware on the selected drive.
Note: Updating drive firmware could take up to 20 minutes to complete.
11 When finished, the Status column of the drive will state Update Complete
and the LEDs on the back of the drive will display:
• Green LED 1 - solid green indicating port connectivity to either the
FC I/O blade or the customer FC switch
• Amber LED - off
• Blue LED - blinks one time per 10 seconds
• Green LED 2 - blinks at the same cadence as the other green LEDs on
the other drives in the module
12 Click Close.
13 Select View > Views. The Manage Views screen displays.
14 Click the Offline button for the partition that contains the replacement
drive. The Change Library Mode screen displays.
15 In the Mode area on the Change Library Mode screen, select Online and
click OK. The Manage View dialog shows the partition now Online.
16 Click Close.
Update the Drive Firmware Using Firmware Images