3. CONFIGURATION

3.1. BASIC CONTROL
With KLIC-DI, the air conditioning unit can be monitored and controlled the same
way it is done with the wired remote control provided with the air conditioning unit.
By means of bus KNX, it can be controlled the following basic functionalities of the
air conditioning system:
ON/OFF of the air conditioning unit.
Setpoint Temperature. Between 16 and 32 ºC.
Operating Mode: Auto, Heat, Dry, Fan and Cool.
Fan Speed: 2 or 3 speed levels configuration. (Check out the available levels in
the Daikin unit)
These functionalities have associated a machine status, which is periodically sent
to KLIC-DI. When KLIC-DI receives a status different from the previous one from the
machine, it updates the status of the corresponding parameter in the bus KNX.
3.2. ADVANCED FUNCTIONALITIES
Besides the basic control over the air conditioning system, KLIC-DI offers other
advanced functionalities that give an added value with regard to the wired remote
control:
Scenes
combination for the air conditioning machine.
Temperature Limitation: Daikin air conditioning systems are limited in
temperature (usually to the range 16-32 ºC. Please verify the range for a
particular model in the corresponding Daikin manual). This KLIC
functionality allows configuring custom temperature ranges for the modes
Heat and Cool by means of the ETS in such a way that the setpoint
temperature will remain in the range. In case of receiving from the bus KNX
a temperature command with a value out of the configured limits, the
temperature value sent to the machine will be the corresponding limit value.