Every error type has associated two communication objects: the binary one
indicates if an error has occurred and the 1-byte object that indicates the code
identifying the error.

4.9. INITIAL CONFIGURATION

The initial configuration window allows configuring the initial machine status after
the installation or a power failure.
The variables that can be initialized are the following:
ON/OFF: Last, ON or OFF.
Temperature: Last or custom.
Mode: Last, auto, heat, dry, fan or cool.
Fan: Last, auto, minimum, minimum-medium, medium, maximum-medium or
maximum.
Moreover, it can be configured the Sending of status to the Bus or Split and when it
must be carried out:
Send Initial Configuration to BUS?: Yes or no.
Delay: number of seconds that the KLIC delays the sending of status to the
BUS