4.2. GENERAL

From the parameterization window General the advanced functionalities can be
enabled:
Scenes
Temperature Limitation
Auto OFF
Errors Management
Type of Control
Indoor Temperature Sending Time
Initial Configuration
As we select the functionalities in the pull down lists, the access to the functionality
configuration window will appear in the Menu at the left and the corresponding
communication objects are enabled.
This window also allows configuring the type of control for the remote control:
Master/Slave
And the Sending Time for the Indoor Temperature. This temperature is sent by the
machine when the indoor temperature changes. In order to avoid an excessive sending