Lutcontrol - Dahua A5A21M/CG9 User Manual

5000 series gige large area scan industrial camera
Table of Contents

Advertisement

5.7

LUTControl

In this property, you can stretch and highlight the gray-level range of the region of interest. The
operation applies to linear curve as well as customized mapping curve, as shown in Figure 5-7; please
refer to Sheet 5-8 for detailed parameter settings.
LUT: short for Look-Up Table.
LUT and Gamma are mutually exclusive. If Gamma is enabled, LUT will not take effect. If LUT is
enabled, Gamma needs to be set to 1.
Parameter
LUTSelector
LUTEnable
LUTIndex
LUTValue
LUTValueAll
5.8
TransportLayerControl
In this property, you can set parameters related to camera's transport layer protocol, as shown in Figure
5-8; please refer to Sheet 5-9 for detailed parameter settings.
Figure 5-7
Sheet 5-8
LUT Control - Parameter Explanation
Explanation
Selects the channel of LUT.
Currently only Luminance(brightness)Look-Up Table is supported.
LUT setting.
1.
Enables LUT for LUT lookup table function.
2.
Sets digital points of the lookup table in LUTIndex with range of
0~4095.
3.
When LUTIndex is selected, you can set corresponding values in
LUTValue.
Sets all the values of Index to the same value.