Menu 9.7.1 - Setting The Heating Mode - RADEMACHER 9485 Instruction Manual For The Electrical Connection And For Commissioning

Duofern room thermostat
Table of Contents

Advertisement

16.4 Menu 9.7.1 - Setting the heating mode

You can set the DuoFern Room Thermostat 9485 for one of the
following heating modes.
There are three heating modes available:
[ 1 ] Room temperature controller (factory setting)
The heating is switched on when the room temperature
drops below the set target temperature.
[ 2 ] Room temperature controller with limiter
This function can be used for floor heating with particularly
sensitive floor coverings. Excessive cooling of the floor can
also be prevented with additional heat sources (e.g. fireplace)
by defining a minimum floor temperature. It is absolutely
essential to connect the device to the external Remote Sensor
9485-F for this heating mode.
The heating is switched on when the room temperature
drops below the set target temperature. The room
temperature is measured with the internal sensor.
The floor temperature is measured by the external Remote
Sensor 9485-F regardless of the room temperature. The set
minimum and maximum floor temperature is taken into
account in the heating control and limited accordingly.
[ 3 ] Cooling function
The air conditioning is switched on when the room
temperature exceeds the set target temperature.
i
Additional parameters must be set in each
heating mode.
EN
81