5
Cabling the Device
This section describes how to cable the device:
Grounding the device – see Section
Connecting to the LAN – see Section
Connecting to a computer for serial communication – see Section
Connecting to power – see Section
5.1
Grounding the Device
The procedure below describes how to ground the device.
The equipment is classified as Class I according to EN-60950-1 and UL 60950-
1 and must be earthed at all times (using an equipment-earthing conductor).
Finland: "Laite on liltettava suojamaadoituskoskettimilla varustettuun
pistorasiaan."
Norway: "Apparatet rna tilkoples jordet stikkontakt."
Sweden: "Apparaten skall anslutas till jordat uttag."
To ground the device:
1.
Connect an electrically earthed strap of 16 AWG wire (minimum) to the chassis' earthing
screw (located on the rear panel), using the supplied washer.
2.
Connect the other end of the strap to a protective earthing. This should be in accordance
with the regulations enforced in the country in which the device is installed.
Hardware Installation Manual
5.1
on page
5.2
5.4
on page
Protective Earthing
Figure 5-1: Grounding the Device
28
28
on page
29
33
Document #: LTRT-41511
Mediant 4000 SBC
5.3
on page
32