Control Mode And Setup - Honeywell IPC500 Installation Manual

Programmable
Table of Contents

Advertisement

Item
Object
TEMP
Object value
PV/SP/DV
Output
operation
Setup
LOW/HIGH
item
content
Output
operation
ON/OFF

4.6 Control mode and setup

Item
Control mode
Control
mode
Mode selection
FIX
control
Control
mode
mode
setup
Program
control
mode
INNER SIGNAL output is to be setup at temperature output.
Setup of which value determines the ON/OFF.
PV: Present value, SP: Set point interlocked with program operation
DV: target value of step (fixed value within step, Destination value)
Setup for ABS or DEV
In case of a setup by selecting object value as SP or DV, and then range
setup and operation direction (ON/OFF) setup are to be done.
range setup : Temperature 2 points MIN~MAX -100.0~300.0°C
ON/OFF setup :
Output On: when ON mode set point is within setup range
Output Off: when ON mode set point is out of setup range
Output On: OFF mode set point is within setup range
Output Off: OFF mode set point is out of setup range
1) FIX control mode
2) Program control mode
Selection available at the operation setup screen
Temperature
-100.0 ~ 300.0°C
setup
Slope
0 ~ 9.9 °C/min
setup
Auto
Auto tuning of PID constant
tuning
Temperature
-100.0 ~ 300.0°C
setup
- 35 -
Specifications
Specifications