Sequence of Operation
1. If each of T1 key (1), T2 key (2), T3 key (3), T4 key(4), T5 key(5) is entered,
the numeric keyboard appears in the lower-hand side of the display. If you enter
the temperature that you want to set and then hit the ENT key, it is set up; if you enter
the ESC key, it is cancelled.
2. If you enter DISP (6) key after executing the sequence of operation 1, it draws a figure
again that divides the field in Figure 3.3.1 according to the changed ZONE field.
3. Temperature range setup for T1 ~ T5 is between -100 and 300°C.
Additional Description
ZONE divisional setup screen
1. Case of maximum 6 Zones
Divided into 1 to 6 zones based upon the setup of T1,T2,T3,T4,T5 in the needs of 6 Zones.
-100°C
2. Case of 1 ZONE
Setup: T1 = 300, T2 = 300, T3 = 300,T4 = 300,T5 = 300 (product prevalues)
-100°C
T1
T2
1
2
3
T3
Temperature SP → High
1
Temperature SP → High
- 16 -
4
5
6
T4
T5
T1
T2
T3
T4
T5
Divided into 6 zones and
setup temperature
300°C
300°C