Additional Description
INNER SIGNAL Explanation
TEMP
PV
Present Value
SP
Set Point
DV
Step
target value
<Figure5.3.4> Block chart when selecting INNER SIGANL
1. Contents
— ON / OFF open collector output × 4 or × 8
— Can be used optionally for cooling and signal control output.
— Each output is independent and sets up temperature, present value/
set point / target value, absolute value / deviation, output operation
(LOW / HIGH), and output operation (ON / OFF)
2. Setup of various operations: Various operations can be set up by combining items below.
— Object : TEMP → It allows you to set up if the object of operation is temperature.
— Object value : PV / SP / DV → It allows you to set up at what point it is ON and OFF.
PV : Present Value
SP : Set Point (Target value that changes synchronously as the PROGRAM
DV : Step's target value (within a step, a fixed value is maintained)
— Operating point : ABS / DEV → sets up absolute value(ABS) and deviation(DEV).
— Output operation : ON / OFF → ON/OFF is set up for operating point in absolute
ABS
Absolute
value(operating
point)
DEV
Deviation
ABS
Absolute
value(operating
ABS
Absolute
value(operating
proceeds)
Only PV allows you to set up. When SP and DV are set, it is fixed
as ABS.
value that is set up next in case object value is SP and DV.
- 23 -
HIGH
Absolute value
1
(ABS VALUE)
LOW
2
HIGH
3
Deviation
(DEVIATION)
LOW
4
ON
5
Minimum value
(MIN VALUE)
OFF
6
ON
7
Minimum value
(MIN VALUE)
OFF
8
Operation
Differential
DELAY
(OPER DIFF)
Operation
DELAY
Differential
(OPER DIFF)
Maximum value
DELAY
(MAX VALUE)
Maximum value
DELAY
(MAX VALUE)