Prerequisites; S4200-On Configurations; Luggage Tag - Dell S4248FB-ON Installation Manual

S4200-on series
Hide thumbs Also See for S4248FB-ON:
Table of Contents

Advertisement

LED
Link/Activity LED—2x50G

Prerequisites

The following is a list of required and optional components for the S4200-ON Series (S4248FB-ON and S4248FBL-ON) switch:
NOTE:
Detailed installation instructions for the S42400-ON Series are provided in
Series.
S4200-ON Series (S4248FB-ON or S4248FBL-ON) switch or multiple switches, if stacking
AC country- and regional-specific cables to connect the AC power source to each of the switches' AC power supplies
Mounting brackets for rack installation, included
Screws for rack installation
#1 and #2 Phillips screw drivers, not included
Torx screwdriver, not included
Ground cable screws, included
Copper or fiber cables
Other optional components are:
Ground cable and lug for the frame-end of the ground cable
Extra power supply unit
Extra fan module
Extra mounting brackets if installing in a four-post rack or cabinet

S4200-ON configurations

You can order the S4200-ON Series (S4248FB-ON and S4248FBL-ON) switch in several different configurations.
S4248FB–ON or S4248FBL-ON AC normal airflow: Forty 1/10GbE SFP+ ports, two 40GbE or 4x1/10GbE QSFP+, and six 100/40GbE
or 4x25/10GbE or 2x50GbE QSFP28 ports, two AC power supplies, and five fan subsystems with airflow from the I/O side to the
power supply side
S4248FB–ON or S4248FBL-ON AC reverse airflow: Forty 1/10GbE SFP+ ports, two 40GbE or 4x1/10GbE QSFP+, and six 100/40GbE
or 4x25/10GbE or 2x50GbE QSFP28 ports, two AC power supplies, and five fan subsystems with airflow from the power supply side to
the I/O side
Fan with airflow from the I/O side to the PSU side
Fan with airflow from the PSU side to the I/O side
AC Power supply with airflow from the I/O side to the PSU side—normal
AC Power supply with airflow from the PSU side to the I/O side—reverse
DC Power supply with airflow from the I/O side to the PSU side—normal
DC Power supply with airflow from the PSU side to the I/O side—reverse

Luggage tag

The S4200-ON Series (S4248FB-ON and S4248FBL-ON) switch has a pull-out tag, known as a luggage tag, on the I/O-side of the switch.
The front of the luggage tag includes switch ID information. The back of the luggage tag includes a QRL that takes you to a Dell EMC
How-To site where you can watch videos about racking the switch, replacing components, configuring port channels, and so on.
Description
Flashing yellow, 1 second on/off—Port beacon
Of —No Link
Flashing yellow—Port activity at 2x50G on a QSFP28 port
Flashing yellow, 1 second on/off—Port beacon
Site Preparations
and
Install the S4200-ON
S4200-ON series switch
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S4248fbl-on

Table of Contents