6.3 MANUAL TEST

The operator can manually perform the indicator and
internal tests at any time during normal radar operation—
just press and release the Test switch. The indicator test
will be performed followed by the display of "PAS" in the
TARGET window in Stationary Mode and in both Target
and PATROL windows in Moving Mode.
NOTE: The unit will remain in the TEST state for 30 seconds
after releasing the TEST switch, indicated by the
flashing TEST indicator. Due to the ability of the
unit to reject non directional signals, the operator
must place the unit in this TEST mode to read tuning
forks.

6.4 TUNING FORK TESTING

Supplied with the FalconHR are two tuning forks, 35 and
65 mph. These tuning forks will simulate targets in the
stationary, moving opposite and moving same direction
modes.
The tuning fork tests should be conducted in an area with
no traffic. If this is not possible, point the FalconHR away
from traffic to avoid reflections from moving vehicles.
6.2