6. TESTING PROCEDURES

6.0 GENERAL

The tuning fork tests explained below should be conducted
at the beginning and end of each patrol shift to ensure the
accuracy and functionality of the unit. The results of these
tests may be recorded in a radar log, similar to the log
found at the end of this manual. The internal circuit and
antenna tests are periodically performed automatically
while the unit is in use.
6.1 POWER ON
Press and release the PWR switch. The unit will light all
the LCD segments and perform a crystal cross check to
verify the accuracy of the speed processing circuitry.
If these tests pass, the unit will display "PAS" in the
TARGET display window, stationary mode, or both target
and PATROL display windows in the moving mode. This
will remain for approximately one (1) second. The displays
will clear and the unit will be operational.
6.2 AUTOMATIC SELF-TEST
As long as the unit is turned on, the FalconHR performs an
internal accuracy test every 5 minutes or whenever the
unit's mode of operation is changed, such as moving to
stationary, and each time the target speed is locked.
This test is automatic and will not interfere with any radar
speed readings being taken. The test passing does not
appear in the displays, but if an error is detected during this
test, the TARGET window will indicate "Err" and further
speed-readings are prohibited.