Thermostat; Electric Ventilation; Water Pump; Electric Fan Check - PIAGGIO MP3 400 i.e. Service Manual

Hide thumbs Also See for MP3 400 i.e.:
Table of Contents

Advertisement

MP3 400 i.e.
For the system venting during the circuit filling step, there is a special union at the top of the head (see
filling rules).
To ensure cooling in case of poor dynamic ventilation, there is an electric fan controlled by the injection
system.
Specification
Cooling system capacity
Prescribed fluid
Sealing pressure
Specification
Starts opening
Specification
Electric ventilation start
Electric ventilation end
Specification
Control
Specification
Specification
Calibration

Electric fan check

- Connect the injection diagnostic tester and select
the menu on the "ERRORS" function.
- Check any failures in the electric fan control cir-
cuit (see "Injection" chapter)
Specific tooling
020460Y Scooter diagnosis and tester
TECHNICAL SPECIFICATIONS

THERMOSTAT

Type

ELECTRIC VENTILATION

Type

WATER PUMP

Type
RADIATOR
Type
EXPANSION TANK
Desc./Quantity
1.8 l
Mixture of 50% water and 50% fluid for sealed cir-
cuits
Cap calibrated at 0.9 bar
Desc./Quantity
Wax-type, with deviator
82 ± 2°C
Desc./Quantity
With piston
107°C
103°C
Desc./Quantity
Centrifugal
Coaxial at the countershaft
Desc./Quantity
Aluminium, with horizontal circulation
Desc./Quantity
Automatic bleeding, in parallel with the radiator
Cooling system
COOL SYS - 3

Advertisement

Table of Contents
loading

Table of Contents