Chapter 4
[CC-40]~[CC-60]
Combinational output terminal
Code/Name
CC-40
Logical calculation
target 1 selection of LOG1
CC-41
Logical calculation
target 2 selection of LOG1
CC-42
Logical calculation
Symbol selection of LOG1
CC-43
Logical calculation
target 1 selection of LOG2
CC-44
Logical calculation
target 2 selection of LOG2
CC-45
Logical calculation
Symbol selection of LOG2
CC-46
Logical calculation
target 1 selection of LOG3
CC-47
Logical calculation
target 2 selection of LOG3
CC-48
Logical calculation
Symbol selection of LOG3
CC-49
Logical calculation
target 1 selection of LOG4
CC-50
Logical calculation
target 2 selection of LOG4
CC-51
Logical calculation
Symbol selection of LOG4
CC-52
Logical calculation
target 1 selection of LOG5
CC-53
Logical calculation
target 2 selection of LOG5
CC-54
Logical calculation
Symbol selection of LOG5
CC-55
Logical calculation
target 1 selection of LOG6
CC-56
Logical calculation
target 2 selection of LOG6
CC-57
Logical calculation
Symbol selection of LOG6
CC-58
Logical calculation
target 1 selection of LOG7
CC-59
Logical calculation
target 2 selection of LOG7
CC-60
Logical calculation
Symbol selection of LOG7
・The logical operation function is used to output the
combinational result of two selected output terminals.
Initial
Range (unit)
value
<Intelligent output
terminal function list>
00
reference
<Intelligent output
terminal function list>
00
reference
00(AND)/01(OR)/
00
02(XOR)
<Intelligent output
terminal function list>
00
reference
<Intelligent output
terminal function list>
00
reference
00(AND)/01(OR)/
00
02(XOR)
<Intelligent output
terminal function list>
00
reference
<Intelligent output
terminal function list>
00
reference
00(AND)/01(OR)/
00
02(XOR)
<Intelligent output
terminal function list>
00
reference
<Intelligent output
terminal function list>
00
reference
00(AND)/01(OR)/
00
02(XOR)
<Intelligent output
terminal function list>
00
reference
<Intelligent output
terminal function list>
00
reference
00(AND)/01(OR)/
00
02(XOR)
<Intelligent output
terminal function list>
00
reference
<Intelligent output
terminal function list>
00
reference
00(AND)/01(OR)/
00
02(XOR)
<Intelligent output
terminal function list>
00
reference
<Intelligent output
terminal function list>
00
reference
00(AND)/01(OR)/
00
02(XOR)
For parameter configuration
Analog output terminal adjustment
Code/Name
Cd-01
[FM] monitor output
wave form selection
Cd-02
[FM] monitor base
frequency (at PWM output)
Cd-03
[FM] Monitor output
selection
Cd-04
[Ao1] Monitor output
selection
Cd-05
[Ao2] Monitor output
selection
Cd-10
Analog monitor adjust
mode enable
Cd-11
Filter time constant of
[FM] monitor
Cd-12
[FM] monitor output
data type selection
Cd-13
[FM] monitor bias
adjustment
Cd-14
[FM] gain adjustment
Cd-15
Output level setting at
[FM] adjustment mode
Cd-21
Filter time constant of
[Ao1] monitor
Cd-22
[Ao1] data type
selection
Cd-23
[Ao1] bias adjustment
Cd-24
[Ao1] gain adjustment
Cd-25
Output level setting at
[Ao1] adjustment mode
Cd-31
Filter time constant of
[Ao2] monitor
Cd-32
[Ao2] data type se
lection
Cd-33
[Ao2] bias adjustment
Cd-34
[Ao2] gain adjustment
Cd-35
Output level setting at
[Ao2] adjustment mode
・Regarding the adjustment method of the Analogue
output, please refer to the chapter 3 example of I/O
terminals adjustment.
4-42
[Cd-01]~[Cd-35]
Initial
Range (unit)
value
00(PWM)/
00
01(Frequency)
2880
0~3600(Hz)
dA-01
Set monitor code
dA-01
dA-01
00(Disable)/
00
01(Enable)
1~500(ms)
10
00(Absolute value)/
00
01(Signed value)
-100.0~100.0(%)
0.0
-1000.0~1000.0(%)
100.0
100.0
0.0~300.0(%)
1~500(ms)
10
00(Absolute value)/
00
01(Signed value)
-100.0~100.0(%)
100.0
-1000.0~1000.0(%)
100.0
0.0~300.0(%)
100.0
1~500(ms)
10
00(Absolute value)/
00
01(Signed value)
-100.0~100.0(%)
0.0
-1000.0~1000.0(%)
100.0
0.0~300.0(%)
100.0