Hitachi P1-00044-L Basic Manual page 101

Sj series
Hide thumbs Also See for P1-00044-L:
Table of Contents

Advertisement

Chapter 4
・Sets the encoder to be input into the optional board,
and sets the motor gear ratio involved in the feedback
of the encoder
[ob-10]~[ob-16] [oE-01]~[oE-27]
P1-FB Pulse train input terminal setting
Code/Name
ob-10
Pulse train
detection object
selection (option)
ob-11
Mode selection of
pulse input (option)
ob-12
Pulse train
frequency scale
(option)
ob-13
Pulse train filter
time constant
(option)
ob-14
Pulse train
bias value (option)
ob-15
Pulse train
detection high limit
(option)
ob-16
Pulse train
detection low limit
(option)
・Set when using the option feedback.
・For more information, refer to the user's guide of the
corresponding option.
P1-FSOptional safety operation setting
Code/Name
00(Warning: with display)/
oC-01
Safety option input
01(Warning: without display)
display selection
oC-10
SS1-A deceleration
0.00~3600.00(s)
time setting
oC-12
0.00~3600.00(s)
SLS-A deceleration time setting
oC-14
SLS-A Speed upper
0.00~590.00(Hz)
limit: (Forward)
oC-15
SLS-A Speed upper
0.00~590.00(Hz)
limit: (Reverse)
oC-16
0.00~3600.00(s)
SDI-A deceleration time setting
00(Limit)
oC-18
01(Invert)
SDI-A limited direction
oC-20
SS1-B deceleration
0.00~3600.00(s)
time setting
oC-22
0.00~3600.00(s)
SLS-B deceleration time setting
oC-24
SLS-B Speed upper
0.00~590.00(Hz)
limit(Forward)
oC-25
SLS-B Speed upper
0.00~590.00(Hz)
limit(Reverse)
oC-26
0.00~3600.00(s)
SDI-B deceleration time
00(Limit)
oC-28
01(Invert)
SDI-B deceleration time setting
・For more detail refer to optional board instruction.
Initial
Range (unit)
00(Frequency reference)/
01(Pulse count)/
02(Speed feedback:
sensor-V/f)
00(90º-phase-shift)/
01(Forward/reverse operation
and direction of rotation)/
02(Forward/reverse operation
with pulse train)
0.05~200.0(kHz)
0.01~2.00(s)
-100.0~100.0(%)
0.0~100.0(%)
0.0~100.0(%)
Initial
Range(unit)
value
30.00
30.00
0.00
0.00
30.00
30.00
30.00
0.00
0.00
30.00
For parameter configuration
P1-AG Optional analog input setting
Code/Name
oE-01
Filter time constant of [Ai4]
oE-03
Start value of [Ai4]
oE-04
End value of [Ai4]
value
oE-05
Start rate of [Ai4]
00
oE-06
End rate of [Ai4]
oE-07
Start point selection of [Ai4]
oE-11
00
Filter time constant of [Ai5]
oE-13
Start value of [Ai5]
oE-14
End value of [Ai5]
50.0
oE-15
Start rate of [Ai5]
oE-16
End rate of [Ai5]
0.10
oE-17
Start point selection of [Ai5]
oE-21
0.0
Filter time constant of [Ai6]
oE-23
Start value of [Ai6]
100.
0
oE-24
End value of [Ai6]
oE-25
Start rate of [Ai6]
0.0
oE-26
End rate of [Ai6]
・Regarding the adjustment method of the analog input,
please refer to the chapter 3 example of I/O terminals
adjustment.
[oE-28]~[oE-49]
P1-AG Optional analog input adjustment
Code/Name
oE-28
00
[Ai4] Voltage/Current zero-bias
adjustment
oE-29
[Ai4] Voltage/Current gain
adjustment
oE-30
[Ai5] Voltage/Current zero-bias
adjustment
oE-31
[Ai5] Voltage/Current gain
00
adjustment
oE-32
[Ai6] Voltage zero-bias
adjustment
oE-33
[Ai6] Voltage gain adjustment
・Regarding the adjustment method of the analog input,
please refer to the chapter 3 example of I/O terminals
adjustment.
00
4-53
Initial
Range (unit)
value
1~500(ms)
8
0.00~100.00(%)
0.00
0.00~100.00(%)
100.00
0.0~[oE-06](%)
0.0
100.0
[oE-05]~100.0(%)
[oE-05]~100.0(%)
100.0
8
1~500(ms)
0.00
0.00~100.00(%)
0.00~100.00(%)
100.00
0.0~[oE-16](%)
0.0
[oE-15]~100.0(%)
100.0
00(Start value)/
01
01(0%)
1~500(ms)
8
0.00~100.00(%)
0.00
0.00~100.00(%)
100.00
0.0~[oE-26](%)
0.0
[oE-25]~100.0(%)
100.0
Initial
Range (unit)
value
-200.00~200.00(%)
0.00
-200.00~200.00(%)
100.00
-200.00~200.00(%)
0.00
-200.00~200.00(%)
100.00
-200.00~200.00(%)
0.00
-200.00~200.00(%)
100.00

Advertisement

Table of Contents
loading

Table of Contents