Chapter 4
[AC-30]~[AC-88]
Setting for two-stage Acc/Decel time
Code/Name
AC-30
Acc. time for Multispeed-1
AC-32
Decel. time for Multispeed-1
AC-34
Acc. time for Multispeed-2
AC-36
Decel. time for Multispeed-2
AC-38
Acc. time for Multispeed-3
AC-40
Decel. time for Multispeed-3
AC-42
Acc. time for Multispeed-4
AC-44
Decel. time for Multispeed-4
AC-46
Acc. time for Multispeed-5
AC-48
Decel. time for Multispeed-5
AC-50
Acc. time for Multispeed-6
AC-52
Decel. time for Multispeed-6
AC-54
Acc. time for Multispeed-7
AC-56
Decel. time for Multispeed-7
AC-58
Acc. time for Multispeed-8
AC-60
Decel. time for Multispeed-8
AC-62
Acc. time for Multispeed-9
AC-64
Decel. time for Multispeed-9
AC-66
Acc. time for Multispeed-10
AC-68
Decel. time for Multispeed-10
AC-70
Acc. time for Multispeed-11
AC-72
Decel. time for Multispeed-11
AC-74
Acc. time for Multispeed-12
AC-76
Decel. time for Multispeed-12
AC-78
Acc. time for Multispeed-13
AC-80
Decel. time for Multispeed-13
AC-82
Acc. time for Multispeed-14
AC-84
Decel. time for Multispeed-14
AC-86
Acc. time for Multispeed-15
AC-88
Decel. time for Multispeed-15
・Individual Acc/Decel times can be set for multispeed
functions[Ab-11]~[Ab-25].
This will be effective only for Acc./Dec.
time if the set frequency is the same.
Speed 3 [Ab-13],
Speed 4 [Ab-14]
Speed 2 [Ab-12]
Speed 1 [Ab-11]
Acc. 1
Acc. 3
Acc. 2
Acc/decel time
[AC-30]
[AC-34]
[AC-38]
Speed 1 Speed
Speed
Multispeed
2
FW
Range (unit)
Unit value
30.00
30.00
30.00
30.00
30.00
30.00
30.00
30.00
30.00
30.00
30.00
30.00
30.00
30.00
30.00
0.00~
3600.00(s)
30.00
30.00
30.00
30.00
30.00
30.00
30.00
30.00
30.00
30.00
30.00
30.00
30.00
30.00
30.00
Same
Decel. 3
Acc. 4
Decel. 3
Acc. 4
Decel. 4
as
[AC-40]
[AC-42]
[AC-40]
[AC-42]
[AC-44]
before
Speed
Speed
Speed
Speed
Speed 4
3
2
4
3
1
For parameter configuration
2nd motor When Intelligent Input terminal 024[SET] is enabled.
Code/Name
AC215 Select method to switch to
Acc2/Decel2 Profile, 2nd-motor
AC216 Acc1 to Acc2 frequency
transition point, 2nd-motor
AC217 Decel1 to Decel2 frequency
transition point, 2nd-motor
AC220 Acceleration time 1, 2nd-motor
AC222 Deceleration time 1, 2nd-motor
AC224 Acceleration time 2, 2nd-motor
AC226 Deceleration time 2, 2nd-motor
Torque control function setting
Code/Name
Ad-01
Torque reference input
source selection
Ad-02
Torque reference value
setting
Ad-03
Polarity selection for
torque reference
Ad-04
Switching time of speed
control to torque control
・Operations settings of torque control.
For more information, refer to the User's guide.
Torque bias setting
Code/Name
Ad-11
Torque bias input
source selection
Ad-12
Torque bias value setting
Ad-13
Polarity selection for torque bias
Ad-14
Terminal [TBS] active
・For setting the torque bias.
For more information, refer to the User's guide.
Speed limitation for torque control
Code/Name
Ad-40
Input selection for
speed limit at torque control
Ad-41
Speed limit at torque
control (at Forward rotation)
Ad-42
Speed limit at torque
control (at Reverse rotation)
・In middle of the torque control the speed limit can be
set.
For more information, refer to the User's guide.
*1)00(Disable)/01(Ai1 terminal)/02(Ai2 terminal)/03(Ai3 terminal)/
07(Parameter)/08(RS485)/13(Pulse train input:main)/ 14(Program
function)/15(PID calc.)
4-17
[AC215]~ [Ad-15]
Range (unit) Initial value
Same as AC115
Same as AC116
Same as AC117
Same as AC120
Same as AC122
Same as AC124
Same as AC126
Initial
Range (unit)
value
07
01~06/09~18 *1)
-500.0~500.0(%)
0.0
00(According
to
sign)/
00
01(Depend on the
operation direction)
0~1000(ms)
0
Initial
Range (unit)
value
01~06/09~18 *1)
07
-500.0~500.0(%)
0.0
00(According
to
sign)/
00
01(Depend on the
operation direction)
00(Disable)/
00
01(Enable)
Range (unit)
Initial value
01~13 *1)
07
0.00
0.00~
590.00(Hz)
0.00