APPENDIX A: FLEXANALOG OPERANDS
Address
FlexAnalog name
13585
RTD Inputs 34 Value
13586
RTD Inputs 35 Value
13587
RTD Inputs 36 Value
13588
RTD Inputs 37 Value
13589
RTD Inputs 38 Value
13590
RTD Inputs 39 Value
13591
RTD Inputs 40 Value
13592
RTD Inputs 41 Value
13593
RTD Inputs 42 Value
13594
RTD Inputs 43 Value
13595
RTD Inputs 44 Value
13596
RTD Inputs 45 Value
13597
RTD Inputs 46 Value
13598
RTD Inputs 47 Value
13599
RTD Inputs 48 Value
13600
Ohm Inputs 1 Value
13601
Ohm Inputs 2 Value
14189
PTP–IRIG-B Delta
24447
Active Setting Group
26161
Therm Mdl Cap Used
26163
Therm Mdl Trip Time
26164
Therm Mdl LkOut Time
26168
Therm Mdl Load
26170
Therm Mdl Curr Unbal
26171
Therm Mdl Bias Load
26172
Starts/hr Lockout
26173
Btwn Starts Lockout
26174
Restrt Delay Lockout
26175
Total Motor Lockout
32768
Tracking Frequency
34752
RRTD RTD 1 Value
34753
RRTD RTD 2 Value
34754
RRTD RTD 3 Value
34755
RRTD RTD 4 Value
34756
RRTD RTD 5 Value
34757
RRTD RTD 6 Value
34758
RRTD RTD 7 Value
34759
RRTD RTD 8 Value
34760
RRTD RTD 9 Value
34761
RRTD RTD 10 Value
34762
RRTD RTD 11 Value
34763
RRTD RTD 12 Value
39168
FlexElement 1 Value
39170
FlexElement 2 Value
39172
FlexElement 3 Value
39174
FlexElement 4 Value
39176
FlexElement 5 Value
M60 MOTOR PROTECTION SYSTEM – INSTRUCTION MANUAL
Units
Description
---
RTD input 34 actual value
---
RTD input 35 actual value
---
RTD input 36 actual value
---
RTD input 37 actual value
---
RTD input 38 actual value
---
RTD input 39 actual value
---
RTD input 40 actual value
---
RTD input 41 actual value
---
RTD input 42 actual value
---
RTD input 43 actual value
---
RTD input 44 actual value
---
RTD input 45 actual value
---
RTD input 46 actual value
---
RTD input 47 actual value
---
RTD input 48 actual value
Ohms
Ohm inputs 1 value
Ohms
Ohm inputs 2 value
ns
PTP time minus IRIG-B time
---
Current setting group
---
Thermal model capacity used
seconds
Thermal model trip time on overload
seconds
Thermal model lockout time
ohms
Thermal model load
---
Thermal model motor unbalance
ohms
Thermal model biased motor load
seconds
Starts per hour lockout time
seconds
Time between starts lockout time
seconds
Restart delay lockout time
seconds
Total motor lockout time
Hz
Tracking frequency
°C
Remote RTD input 1 actual value
°C
Remote RTD input 2 actual value
°C
Remote RTD input 3 actual value
°C
Remote RTD input 4 actual value
°C
Remote RTD input 5 actual value
°C
Remote RTD input 6 actual value
°C
Remote RTD input 7 actual value
°C
Remote RTD input 8 actual value
°C
Remote RTD input 9 actual value
°C
Remote RTD input 10 actual value
°C
Remote RTD input 11 actual value
°C
Remote RTD input 12 actual value
---
FlexElement 1 actual value
---
FlexElement 2 actual value
---
FlexElement 3 actual value
---
FlexElement 4 actual value
---
FlexElement 5 actual value
FLEXANALOG ITEMS
A
A-9

Advertisement

Table of Contents
loading