FLEXLOGIC
Operand type
RxGOOSE Boolean
Virtual Input
Virtual Output
The following table lists alphabetically the operands available for the relay.
Table 5-17: M60 FlexLogic operands
Operand type
CONTROL
PUSHBUTTONS
DIRECT DEVICES
DIRECT INPUT/
OUTPUT CHANNEL
MONITORING
5
ELEMENT:
AMP unbalance
ELEMENT:
Auxiliary overvoltage
ELEMENT:
Auxiliary
undervoltage
ELEMENT
Breaker flashover
5-136
State
Example of format
On
RxGOOSE Boolean 1 On
On
Virt Ip 1 On
On
Virt Op 1 On
Operand syntax
CONTROL PUSHBTN 1 ON
CONTROL PUSHBTN 2 ON
CONTROL PUSHBTN 3 ON
CONTROL PUSHBTN 4 ON
CONTROL PUSHBTN 5 ON
CONTROL PUSHBTN 6 ON
CONTROL PUSHBTN 7 ON
DIRECT DEVICE 1On
DIRECT DEVICE 16On
DIRECT DEVICE 1Off
DIRECT DEVICE 16Off
DIR IO CH1 CRC ALARM
DIR IO CH2 CRC ALARM
DIR IO CH1 UNRET ALM
DIR IO CH2 UNRET ALM
AMP UNBALANCE 1 PKP
AMP UNBALANCE 1 OP
AMP UNBALANCE 1 DPO
AMP UNBALANCE 2...
AUX OV1 PKP
AUX OV1 DPO
AUX OV1 OP
AUX OV2 to AUX OV3
AUX UV1 PKP
AUX UV1 DPO
AUX UV1 OP
AUX UV2 to AUX UV3
BKR 1 FLSHOVR PKP A
BKR 1 FLSHOVR PKP B
BKR 1 FLSHOVR PKP C
BKR 1 FLSHOVR PKP
BKR 1 FLSHOVR OP A
BKR 1 FLSHOVR OP B
BKR 1 FLSHOVR OP C
BKR 1 FLSHOVR OP
BKR 1 FLSHOVR DPO A
BKR 1 FLSHOVR DPO B
BKR 1 FLSHOVR DPO C
BKR 1 FLSHOVR DPO
BKR 2 FLSHOVR...
Characteristics
[Input Is '1' (= ON) if...]
The RxGOOSE Boolean is presently in the ON state
The virtual input is presently in the ON state
The virtual output is presently in the set state (that is,
evaluation of the equation that produces this virtual output
results in a "1")
Operand description
Control pushbutton 1 is being pressed
Control pushbutton 2 is being pressed
Control pushbutton 3 is being pressed
Control pushbutton 4 is being pressed
Control pushbutton 5 is being pressed
Control pushbutton 6 is being pressed
Control pushbutton 7 is being pressed
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
Flag is set, logic=1
The rate of direct input messages received on channel 1 and failing the CRC
exceeded the user-specified level.
The rate of direct input messages received on channel 2 and failing the CRC
exceeded the user-specified level.
The rate of returned direct input/output messages on channel 1 exceeded
the user-specified level (ring configurations only).
The rate of returned direct input/output messages on channel 2 exceeded
the user-specified level (ring configurations only).
AMP unbalance 1 element is picked up
AMP unbalance 1 element is operated
AMP unbalance 1 element is dropped out
Same set of operands as shown for AMP UNBALANCE 1
Auxiliary overvoltage element has picked up
Auxiliary overvoltage element has dropped out
Auxiliary overvoltage element has operated
Same set of operands as shown for AUX OV1
Auxiliary undervoltage element has picked up
Auxiliary undervoltage element has dropped out
Auxiliary undervoltage element has operated
Same set of operands as shown for AUX UV1
Breaker 1 flashover element phase A has picked up
Breaker 1 flashover element phase B has picked up
Breaker 1 flashover element phase C has picked up
Breaker 1 flashover element has picked up
Breaker 1 flashover element phase A has operated
Breaker 1 flashover element phase B has operated
Breaker 1 flashover element phase C has operated
Breaker 1 flashover element has operated
Breaker 1 flashover element phase A has dropped out
Breaker 1 flashover element phase B has dropped out
Breaker 1 flashover element phase C has dropped out
Breaker 1 flashover element has dropped out
Same set of operands as shown for BKR 1 FLSHOVR
M60 MOTOR PROTECTION SYSTEM – INSTRUCTION MANUAL