Basic Installation Requirements - Growatt SPH3000 Installation & Operation Manual

Sph series
Hide thumbs Also See for SPH3000:
Table of Contents

Advertisement

4
Unpacking
Growatt SPH series and accessories as follows:
Item
Number
Description
SPH inverter
A
1
User Manual
B
1
Paper board(installation guide)
C
1
Waterproof cover
D
1
AC Grid connector
E
1
EPS output connector
F
1
Communication cable
G
1
Current sensor
H
1
Lead-acid battery temperature sensor
I
1
RJ45 connector
J
1
M6 setscrew
K
4
Battery power terminal
M
2
Screw
N
6
MC4 connector
O/P
2/2
11
Chart 4.1

5.1 Basic installation requirements

A. The installation location must be suitable for SPH's weight for a long period time
B. The installation location must conforms with dimension of SPH
C. Do not install the unit on structures constructed of flammable or thermo labile
materials
D. The Ingress Protection rate is IP65 and the pollution degree is PD2. Please refer to
the below:
Chart 5.1
E. Battery installation option is not far away from the position of SPH, the length
between SPH and battery should not be more than 1.5m.
F. The ambient temperature should be -25℃ ~60 ℃
G. SPH can be installed in vertical or lean back on plane, Please refer to the below
Chart 5.2
5
Installation
12