Brother HL-730Plus Service Manual page 76

Hide thumbs Also See for HL-730Plus:
Table of Contents

Advertisement

M-7
BD failure
Possible cause
Step
Harness
1
connection
failure
M-8
Scanner failure
Possible cause
Step
Harness
1
connection
failure
Power supply
2
input
Check
Is the connection of connector P2
on the panel sensor PCB correct?
Check
Is the connection of the scanner
motor connector and connector P3
on the panel sensor PCB correct?
Is the voltage between pins 1 (+24
VDC) and 2 (GND) of connector P3
on the panel sensor PCB measured
24 VDC?

Result
Remedy
No
Connect it securely.
Result
Remedy
No
Connect the
connectors securely.
No
Check if +24 VDC is
supplied between pins
1 (+24 VDC) and 3
(GND) of connector
P4 on the panel
sensor PCB.
If not, check the power
supply input.
Yes
Replace the scanner
unit.