9
Set-up
9
Inserting the needle
.01
Fig. 9 - 01
Observe and comply with all regulations and instructions in this instruction
manual.
Pay particular attention to all safety regulations!
All set-up work may only be carried out by appropriately instructed personnel.
Disconnect the machine from the electricity mains for all set-up work by operat-
ing the main switch or by removing the mains plug!
Switch off the machine!
Risk of injury due to accidental
machine start-up!
Only use needles of the system
intended for the machine, see
Chapter 3 Technical Data!
1
Bring the needle bar to the top position.
2
Loosen the screw 1 and insert the nee-
dle 2 until you feel it stop. The long
groove must point forwards.
Tighten the screw 1.
Set-up