Adjustment
13
Front connecting rod of the top feed
.06.13
Move needle bar to 0.8 before t.d.c.
Loosen screw 1.
Adjust connecting rod 2 in accordance with the rule.
Tighten screw 1.
Check the setting.
80
Rule
In needle bar position 0.8 mm before t.d.c (Adjustment hole 4) there should be a clear-
ance of approximately 16.5 mm between the eye of connecting rod 2 and the machine
housing 3.
1
16.5 mm
3
2
Fig. 13 - 13
2
3
5
4
1