C.2 Transportation Environment - Huawei iSiteC BTS3601C-800 User Manual

Cdma base station
Table of Contents

Advertisement

User Manual
iSiteC BTS3601C CDMA Base Station
The density of chemical active substances shall meet the requirements listed in
l
Table C-3.  
Table C-3 Requirements on the density of chemical active substances
Chemical active substance
IV. Mechanical stress 
Table C-4 Requirements on mechanical stress
Sinusoidal vibration
Unsteady impact
Note: 
Impact response spectrum: The max. acceleration response curve generated by the equipment under the
specified impact excitation. Impact response spectrum II indicates that the duration of semi sinusoidal impact
response spectrum is 6ms.  
Static load capability: The capability of the equipment in package to bear the pressure from the top in normal
pile-up method.

C.2 Transportation Environment 

I. Climate environment 
Table C-5 Requirements on climate environment
Altitude
Air pressure
Temperature
Temperature change rate
Relative humidity
Solar radiation
Thermal radiation
Wind speed
SO
2
H
S
2
NO
2
NH
3
Cl
2
HCl
HF
O
3
Item
Displacement
Acceleration
Frequency range
Impact response
spectrum II
Static load capability
Item
Appendix C Environment Requirement
Unit
mg/m³
mg/m³
mg/m³
mg/m³
mg/m³
mg/m³
mg/m³
mg/m³
Sub-item
Ÿ 7.0mm
-
2~9Hz
Ÿ 250m/s²
Ÿ 5kPa
Ÿ 5,000m
70kPa~106kPa
-40~+70 Celsius degree
Ÿ 3 Celsius degree/min
10%~100%
Ÿ 1,120W/s²
Ÿ 600W/s²
Ÿ 30m/s
C-2
System Description
Content
Ÿ 0.30
Ÿ 0.10
Ÿ 0.50
Ÿ 1.00
Ÿ 0.10
Ÿ 0.10
Ÿ 0.01
Ÿ 0.05
Range
-
Ÿ 20.0m/s²
9~200Hz
Range