Max. welding voltage
Open circuit voltage
Degree of protection
Type of cooling
Insulation class
EMC emission class
Marks of conformity
Safety symbol
Dimensions l x w x h
Weight
1)
connected to public grid at 230/400 V and 50 Hz
2)
d.c. = Duty cycle
CMT 4000 Ad-
Mains voltage
vanced MV
Mains voltage tolerance
Mains frequency
Mains fuse protection
Mains connection
Primary continuous current
Primary continuous power
Cos phi
Efficiency
Welding current range
Welding current at
Welding voltage range according to standard characteristic
Max. welding voltage
Open circuit voltage
Degree of protection
Type of cooling
Insulation class
EMC emission class
Marks of conformity
Safety symbol
1)
MIG/MAG
Rod electrode
10 min / 40 °C (104 °F)
MIG/MAG
Rod electrode
625 x 290 x 705 mm
24.61 x 11.42 x 27.76 in.
119.49 lb.
3 x 200-240 V
3 x 380-460 V
50 / 60 Hz
63/35 A slow-blow
Restrictions possible
2)
100% d.c.
13.0 - 16.0 kVA
10 - 400 A
2)
40 % d.c.
2)
60 % d.c.
2)
100% d.c.
14.2 - 34.0 V
20.4 - 36.0 V
-
90 V
IP 23
AF
F
A
CE
S
54.2 kg
+/- 10 %
-
0.99
-
3 - 400 A
400 A
350 A
290 A
-
90 V
IP 23
AF
F
A
CE, CSA
S
191