Fronius TransSynergic 5000 Operating Instructions & Spare Parts page 133

Mig/mag power source
Hide thumbs Also See for TransSynergic 5000:
Table of Contents

Advertisement

As long as the power source is switched on, the corrected parameter values remain saved.
After the power source has been switched on again, the parameters are reset to the per-
manently settable values.
"Minimum" and "maximum" are used for setting ranges that differ according to power
source, wire-feed unit, welding program, etc.
PcH
Power correction High - Correction boundary (high) for the welding power
Unit
Setting range
Factory setting
NOTE! The maximum amount by which parameter P can be increased is the val-
ue set for PcL.
PcL
Power correction Low - Correction boundary (low) for the welding power
Unit
Setting range
Factory setting
NOTE! The maximum amount by which parameter P can be decreased is the val-
ue set for PcL.
AL.c
Arc length correction (up or down)
Unit
Setting range
Factory setting
NOTE! The maximum amount by which parameter AL.1 can be increased or de-
creased is the value specified for AL.c.
JSL
Job Slope - defines the time between the job that is currently selected and the next job
Unit
Setting range
Factory setting
% (of permanently settable parameter P - power correction)
0 - 20
0
% (of permanently settable parameter P - power correction)
0 - 20
0
% (of permanently settable parameter AL.1)
0 - 30
0
s
OFF or 0.1 - 9.9
OFF
131

Advertisement

Table of Contents
loading

Table of Contents