Fronius TransSynergic 5000 Operating Instructions & Spare Parts page 138

Mig/mag power source
Hide thumbs Also See for TransSynergic 5000:
Table of Contents

Advertisement

Fdi
Feeder inching
Unit
Setting range
Factory setting
Fdi
(z.B. 22)
Passage over time of the wire feed speed when the
feeder inching button is pressed and held down
If the Feeder inching button is released and pressed again before one second has elapsed,
the sequence starts again from the beginning. This makes it possible to position the wire
continuously at the low wire feed speed of 1 m/min or 39.37 ipm when necessary.
bbc
Burn-back time correction
Unit
Setting range
Factory setting
dYn
dynamic - Arc force dynamic correction
Unit
Setting range
Factory setting
136
NOTE! If Fdc is set to AUT, the value from the welding program database will be
used. If Fdc values are set manually and these values are faster than the wire
feed speed that was set for the welding operation then the feeder creep speed is
equal to the wire feed speed set for the welding operation.
m/min
1 - max.
10
NOTE! To facilitate the exact positioning of the wire electrode, the following se-
quences are possible when the welder presses and holds the Feeder inching but-
ton down:
1
1
2
2,5
3
s
± 0.20
0
1
± 5
-
ipm
39.37 - max.
393.7
-
Hold down the button for up to one se-
cond ... Irrespective of the value that
has been set, the wire feed speed re-
mains at
1 m/min or 39.37 ipm for the first se-
cond.
-
Hold the button for up to 2.5 seconds
... After one second, the wire feed
speed increases at a uniform rate over
the next 1.5 seconds.
-
Hold the button for longer than 2.5 se-
t (s)
conds ... After a total of 2.5 seconds,
the wire is fed at a constant rate equal
4
5
to the wire feed speed set for the Fdi
welding parameter.