Cmt 4000 Advanced - Fronius TransSynergic 5000 Operating Instructions & Spare Parts

Mig/mag power source
Hide thumbs Also See for TransSynergic 5000:
Table of Contents

Advertisement

Welding current at
Welding voltage range according to standard characteristic
Max. welding voltage
Open circuit voltage
Degree of protection
Type of cooling
Insulation class
EMC emission class
Marks of conformity
Safety symbol
Dimensions l x w x h
Weight
1)
2)
3)
CMT 4000 Ad-
Mains voltage
vanced
Mains voltage tolerance
Mains frequency
Mains fuse protection
Mains connection
Primary continuous current
Primary continuous power
Cos phi
Efficiency
Welding current range
Welding current at
Welding voltage range according to standard characteristic
190
connected to public grid at 230/400 V and 50 Hz
PCC = Interface to the public grid
d.c. = Duty cycle
1)
TIG
10 min / 40 °C (104 °F)
TIME
MIG/MAG
Rod electrode
TIG
MIG/MAG
Rod electrode
10 min / 40 °C (104 °F)
MIG/MAG
Rod electrode
3)
40 % d.c.
3)
60 % d.c.
3)
100% d.c.
28.0 - 48.0 V
14.2 - 39.0 V
20.4 - 40.0 V
10.1 - 30.0 V
626 x 287 x 477 mm
24.65 x 11.30 x 18.78 in.
35 A slow-blow
Restrictions possible
2)
100% d.c.
2)
40 % d.c.
2)
60 % d.c.
2)
100% d.c.
14.2 - 34.0 V
20.4 - 36.0 V
3 - 500 A
500 A
450 A
360 A
48 V
70 V
IP 23
AF
F
A
CE
S
37.4 kg
82.45 lb.
3 x 400 V
+/- 15 %
50 / 60 Hz
-
15 kVA
0.99
-
3 - 400 A
10 - 400 A
400 A
360 A
300 A

Advertisement